POWER'VT®WATER HEATER
• Water temperature aver 12S"f
ccn
couse severe burns Instantly
or death from scalds.
• Children. disabled and elderly are
at highest risk of being scolded.
• See instruction manual before
setting temperature at water
heater.
• Feel water before bathing
or showering.
• If this appliance is used ta
produce water that could scald
if too hot, such as domestic hot
water use, adjust the outlet control
(limit) or use temperature limiting
valves to obtain a maximum water
temperature of 12S·F.
WARNING
This water heater is equipped with
an
adjustable thermostat
to
control water
temperature. Hot water temperatures
required for automatic dishwasher and
laundry use could cause scald iJums
resulting in serious personal injury
and/or death. The temperature at ,which
injury occurs varies with the person's
age and time of exposure. The slower
response
time
of disabled persons
increases the hazards to them. Never
allow small children to use
a
hot water
tap or to' draw their own bath water.
Never leave
a
child or disabled person
unattended in
a
bathtub or shower.
Since
the
thermostat
temperature
setting could be set too high, adjust the
thermostat temperature setting to
125°F
or lower. Lower settings help reduce risk
of scald injury. Remember, no water
heater
system
will
provide
exact
temperature at all tim.es. Allow
a
few
days of operation at this setting to
determine
the
correct
temperature
setting consistent with your needs and
remember, "Hotter water increases the
risk of scald injury." Also, the water
heater should be located in an area
where the general public does not have
access to set temperatures.
ELECTRICAL
1.
Wiring to the unit should conform
'0
the
National Electrical Code or the code legally
authorized in your locality. A fused disconnect
switch should be used for the water heater.
When
required,
PVI' water
heaters
are
equipped with step-down transformers 10cated
within the NEMA enclosure. This allows for an
effective single point electrical connection to
the water heater.
2. Be certain that high and low Yoltages are
connected to the correct points.
3. When remote on/off, air praying interlock, or
lead-lag enable operation is used, remove
jumper from R1 and R2 and wire in series.
4. A proper earth ground for this unit must be
provided. PVI recommends a single conductor
ground wire be pulled from the' distribution
panel to the sub panel (or some similar type).
NOTE: Use only copper wiring of proper sizing for incoming service. Damage resulting from use
of aluminum wiring will be excluded from coverage under the warranty of this unit