BGD36CF TOP OR REAR EXIT VERTICAL TERMINATION
when (H
) < (V
)
T
T
Simple venting confi gurations
FIGURE 33
REQUIRED
VERTICAL RISE
IN FEET
V
T
HORIZONTAL VENT RUN PLUS OFFSET IN FEET
The shaded area within the lines represents acceptable
values for H
and V
.
T
T
See graph to determine the required vertical rise V
required horizontal run H
.
T
For vent confi gurations requiring more than zero 90° elbow
(top exit) or one 90° elbow (rear exit), the following formulas
apply:
Formula 1: H
< V
T
Formula 2: H
+ V
T
T
for the
T
T
< 40 feet
Example 6:
FIGURE 34
V
= 5 ft
1
V
= 10 ft
2
V
= V
+ V
T
1
2
H
= 3 ft
1
H
= 2.5 ft
2
H
= H
+ H
R
1
2
H
= .03(three 90° elbows - 90°)
O
= .03(90 + 90 + 90 - 90) = 5.4 ft
H
= H
+ H
T
R
O
H
+ V
= 10.9 + 15 = 25.9 ft
T
T
Formula 1:
H
< V
T
10.9 < 15
Formula 2:
H
+ V
H
T
T
25.9 < 40
Since both formulas are met, this vent confi guration is
acceptable.
90°
H
2
V
1
H
1
90°
= 5 + 10 = 15 ft
= 3 + 2.5 = 5.5 ft
= 5.5 + 5.4 = 10.9 ft
T
< 40 feet
T
W415-0566 / D / 08.30.07
17