Performance to published specifications and operational life of these modules are covered by ATI's standard warranty on the SYSTEM 10K only when they are used as part of a SYSTEM 10K consisting of an RM100 Rack Enclosure and PS100 Power Supplies.
Page 3
Instead, connect the unbalanced load between the HI output and DC GROUND (rather than HI and LO) or use a transformer output equipped DA module such as an ATI MIDA100-1 or isolate the unbalanced load through a balanced-to-unbalanced converter such as an ATI L1000-1 Line Amplifier or an isolation transformer.
All parts with the exception of panels, shields and PC boards are standard distributor items but are also available from ATI stock. A1 and A4 are National LF347N quad bi-fet ICs interchangeable with TI TL074 and others. A2 and A3 are Signetics, TI or Exar NE5532AN dual, high output audio opamps.
>90 dB @ 1KHz ENVIRONMENTAL Power Supply 120 or 230 VAC ±10% @50/60 Hz (determined by power supply wiring) Operating Temperature 0 deg C to 40 deg C Humidity 0 to 90% non-condensing ■ sales@atiaudio.com ATI Audio Inc. ■ Tel: 856-626-3480 audio.com...
Page 6
ATI warrants this product to be free from defects in materials and workmanship to its original owner for a period of one year from date of purchase. ATI will repair or replace such product or part thereof, which upon inspection by ATI, is found to be defective in materials or workmanship.