MODEL
Output Power
Frequency Response
Input Sensitivity
Maximum Input Level
Input Impedance Active Balanced
S/N Ratio A-Weighted RMS
Crosstalk at rated output power 8 Ohm
1KHz
Damping factor at 1KHz 8 Ohm
Slew Rate Internal
Protection
Cooling
Power Supply
Dimensions (mm)
C2 Series
Stereo 8 Ohm
300W + 300W
Stereo 4 Ohm
450W + 450W
Bridge 8 Ohm
Parallel 8 Ohm
Parallel 4 Ohm
10Hz-50KHz
0,77V/26dB/1,4V
Short circuit, current
limited, DC fault, AC
line fuse, thermal
cut off, power
up/down transients,
C2-450
400W + 400W
650W + 650W
800W
10Hz-50KHz
-1,5dB
0,77V/26dB/1,4V
2 Volt
20k Ohms
>90dB
>70dB
>150
30V/µs
Short circuit, current
limited, DC fault, AC
line fuse, limiter,
thermal cut off,
power up/down
slow start
transients, slow
Variable Speed Fan
230V-50Hz
483 x 430 x 132
C2-650
450 W + 450W
780W + 780W
1000W
10Hz-50KHz
-1,5dB
0,77V/26dB/1,4V
2 Volt
20K Ohms
>95dB
>70dB
>200
35V/µs
Short circuit, current
limited, DC fault, AC
line fuse, limiter,
thermal cut off,
power up/down
transients, slow
start
C2-800
1300W
-1,5dB
2 Volt
20K Ohms
>100dB
>70dB
>200
40V/µs
start
11