Monitor Connection; Power Connection - Vision IMC-922 User Manual

Hd-sdi camera
Table of Contents

Advertisement

Page 6
3.
Other Device Connection
3.1.

Monitor Connection

Connect the HD-SDI output of the monitor to the BNC connector of the camera by Coaxial
cable. If the monitor does not support HD-SDI output, you have to use HD-SDI converter.
Video output type could be set as NTSC or PAL.
3.2.
Video Cable Connection
Refer to following table regarding the cable. If the distance between the camera and the
monitor is over maximum video transmission distance, separate video amp is required to use.
* Maximum HD-SDI transmission distance depends on cable manufacturer and installation
environment.
Maximum Transmission Distance
100 ~ 140m
200m
3.3.

Power Connection

For easy installation, IMI TECH provides special power cable to connect DC jack type of
power adapter. Connect the camera to the device, which its power is turned off.
* Camera operation guarantee power: DC 12V ~ 24V ±10%
3.4.
RS-485 Connection
Using RS-485 communication, it can be possible to control OSD menu in external device.
Cable Requirement
5C2V, 75ohm
L-6CHD, 75ohm (HDTV-SDI Cable)