TABLE 12: COMPUTER TERMINAL COMMANDS FOR RS-232 INTERFACE
Command
Description
sst
Unit position
psn
fpw
Forward PW
Reflected PW
rpw
t1
t2
tfs
dnl
Tx start condition
stc
For txg and nam: after typing the command, type a space and then the value. Then press the
[Enter] key.
(continued)
Status
Displays the system status (redundant system only).
Displays the position of the SSPB in the redundant
system. (A or B, redundant system only)
Displays the forward transmission output power in dBm.
Displays the reflected transmission power in dBm.
Hand held
Selects the hand-held Terminal Mode.
PC term
Selects the PC Terminal Mode.
Displays the frequency of the transmission path Local
Tx freq shift
Oscillator.
download
Allows the unit to go into the download mode.
Allows for the start condition of the unit to be: on, mute,
or as the previous condition