Download Print this page

Performax 241-0916 Operator's Manual page 22

18v lithium-ion hammer drill

Advertisement

BATTERY PACk REMOVAL AND PREPARATION FOR RECYCLING
To preserve natural resources, please recycle or dispose of batteries properly. This
product contains lithium-ion batteries. Local, state, or federal laws may prohibit
disposal of lithium-ion batteries in ordinary trash. Consult your local waste authority
for information regarding available recycling and/or disposal options.
Warning: Upon removal of the battery pack for disposal or recycling, cover
the battery pack's terminals with heavy-duty adhesive tape. Do not attempt to
destroy or disassemble battery pack or remove any of its components. Lithium-
Ion batteries must be recycled or disposed of properly. Also, never touch both
terminals with metal objects and/or body parts as short circuit may result. Keep
away from children. Failure to comply with these warnings could result in fire
and/or serious injury.
CHUCk REMOVAL (Fig. 13)
The chuck can be removed and replace
with a new one.
1. Lock the trigger switch by placing the
direction of rotation selector in the
center position.
2. Open the chuck jaws. Using a
screwdriver, remove the chuck screw
by turning it in a clockwise direction.
3. Insert a 5/16-in. or larger hex key into
the chuck of the drill and tighten the chuck jaws securely.
4. Tap the hex key sharply with a mallet in a anti-clockwise direction. This will
loosen the chuck for easy removal.
5. Attach a new chuck to the spindle and tighten the chuck screw.
Fig. 13
Mallet
Hex key
22
Chuck jaws

Advertisement

loading