INSTALLER:
LEAVE THESE
INSTRUCTIONS
WITH
THE HOMEOWNER.
HOMEOWNER:
RETAIN
THESE
INSTRUCTIONS
FOR FUTURE
REFERENCE.
Wiring
Diagrams
are
included
in this
package.
INSTALLATION
INSTRUCTIONS
FOR FREESTANDING
36"
GAS RANGE
Before
you begin,
read the following
instruc-
tions
completely
and carefully.
If followed,
they
will
simplify
the installation
job.
IMPORTANT:
OBSERVE
ALL
GOVERNING
CODES
AND ORDINANCES.
Input
ratings
shown
on the rating
plate(serlal
tag1 are for elevations
up to 2,000
feet.
For elevations
above
2,000
feet, ratings
should
be
reduced
at a rate
of 4%
for each
1.000
feet
above
sea level.
2.
PROPER
GAS SUPPLY
This range is manufactured
for use with NATURAL
GAS.
It can be converted
for use on LP GAS. The rating plate lo-
cated under the main top has the Information
on the type
of gas this range can be used with. When in doubt check
with your local gas supplier.
Provide a gas supply line to the range location. We sug-
gest using a
z/4"
rigid pipe, as smaller size pipe on long runs
may result in the gas supply not being sufficient.
Pipe joint
compounds
resistant
to the action of LP gas must be
used.
The supply line should be equipped with a shutoff valve.
This valve should always be located in the same room as
the range and should be in a locatlon that allows ease of
opening and closing. Do not block access to the shutoff
valve.
If local codes permit,
It
IS
recommended
that flexible
metal tubing design-certified
by the American Gas Asso-
ciation, be used for connecting
the appliance to the gas
supply line. [The gas valve connection
will
accept
a 3/a"
male pipe thread.1
If rigid pipe is used as a gas supply line, a combination
of
pipe fittings
must be used to obtain an In-line connectlon
to the range.
INSTALLATION
REQUIREMENTS
6
This
lnstallatlon
must
conform
with
the American
Natlonal
Stand-
ard, Natlonal
Fuel Gas Code
ANSI
2223.1-l
980
l
and local codes
and ordinances
MOBILE
HOMC
INSTALLATION
REGUIREMENTS
ARE
LISTED
BELOW
ON PAGE 4.
The gas pressure
regulator
on this model IS convertible
and must be used. This regulator
can be used on either
NATURAL
or LP gases. The pressure
regulator
has fixed
outlet pressure
at NATURAL
and LP settings
and these
cannot be changed. The fixed outlet pressure
on NATU-
RAL gas setting
is 4 Inches WC. On the!LP gas setting
the outlet pressure
is 10 Inches WC.
l
Copies of the standard
listed above may be obtalned from:
AMERICAN
GAS ASSOCIATION
1515 Wilson Boulevard
Arlington,
Virginia 22209
1