Overhaul; Recovering/Recycling Of Nimh Hv Battery Pack - Toyota PRIUS 2012 Manual

Emergency response guide
Hide thumbs Also See for PRIUS 2012:
Table of Contents

Advertisement

Emergency Response (Continued)

Overhaul

During overhaul, immobilize and disable the vehicle if not already done.
Refer to illustrations on page 17, 18, 19 and 20. The HV battery cover should
never be breached or removed under any circumstances including fire. Doing
so may result in severe electrical burns, shock, or electrocution.
Immobilize Vehicle
Chock wheels and set the parking brake.
Move the shift lever to the Park position.
Disable Vehicle
Performing either of the following two procedures will shut the
vehicle off and disable the HV battery pack, SRS, and gasoline fuel
pump.
Procedure #1
Mechanical Ignition Key System (Standard Equipment):
1.
Confirm the status of the READY indicator in the instrument
cluster.
2.
If the READY indicator is illuminated, the vehicle is on and
operational. Shut off the vehicle by turning the ignition key off,
removing the ignition key and placing it on the dash.
Disconnect the 12 Volt auxiliary battery under the passenger side
3.
rear seat.
Smart Key System (Optional Equipment):
1.
Confirm the status of the READY indicator in the instrument
cluster.
2.
If the READY indicator is illuminated, the vehicle is on and
operational. Shut off the vehicle by pushing the power button
once.
3.
The vehicle is already shut off if the instrument cluster lights and
the READY indicator are not illuminated. Do not push the
power button because the vehicle may start.
4.
If the smart key is easily accessible, keep it at least 16 feet (5
meters) away from the vehicle.
Disconnect the 12 Volt auxiliary battery under the passenger side
5.
rear seat to prevent accidental restarting of the vehicle.
Procedure #2 (Alternate if power button or ignition key is
inaccessible)
1.
Open the hood and remove the fuse box cover.
2.
Remove the IG2 fuse (30A green colored) in the engine
compartment fuse box as illustrated on page 20. If the correct
fuse cannot be recognized, pull all fuses in the fuse box.
3.
Disconnect the 12 Volt auxiliary battery under the passenger side
rear seat.
NOTE:
Before disconnecting the 12 Volt auxiliary battery, if necessary,
lower the windows, unlock the doors and open the back door as
required. Once the 12 Volt auxiliary battery is disconnected, power
controls will not operate.
WARNING:
The high voltage system may remain powered for up to 10 minutes
after the vehicle is shut off or disabled. To prevent serious injury
or death from severe burns or electric shock, avoid touching,
cutting, or breaching any orange high voltage power cable or high
voltage component.
The SRS may remain powered for up to 90 seconds after the vehicle
is shut off or disabled. To prevent serious injury or death from
unintentional SRS deployment, avoid breaching the SRS
components.
If none of the disabling procedures can be performed, proceed with
caution as there is no assurance that the high voltage electrical
system, SRS, or fuel pump are disabled

Recovering/Recycling of NiMH HV Battery Pack

Clean up of the HV battery pack can be accomplished by the vehicle recovery
crew without further concern of runoff or spillage. For information regarding
recycling of the HV battery pack, contact the nearest Toyota dealer, or:
United States: (800) 331-4331
Canada: (888) TOYOTA 8 [(888) 869-6828]
-25-
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yaris hybrid 2012