Vermont Castings Encore 2040CE Installation And Operating Manual
Vermont Castings Encore 2040CE Installation And Operating Manual

Vermont Castings Encore 2040CE Installation And Operating Manual

Non-catalytic / catalytic woodburning stove
Hide thumbs Also See for Encore 2040CE:

Advertisement

SaFeTy NoTice: iF ThiS appliaNce iS NoT pRopeRly iNSTalleD, opeRaTeD aND MaiN-
TaiNeD, a hoUSe FiRe May ReSUlT.
To ReDUce The RiSk oF FiRe, Follow The iNSTallaTioN iNSTRUcTioNS. FailURe To
Follow iNSTRUcTioNS May ReSUlT iN pRopeRTy DaMage, boDily iNjURy oR eveN
DeaTh. coNTacT local bUilDiNg oFFicialS aboUT ReSTRicTioNS aND iNSTallaTioN
iNSpecTioN ReqUiReMeNTS iN yoUR aRea.
Do Not Discard This Manual: Retain for Future Use
encore
Non-catalytic / catalytic
woodburning Stove
Model 2040ce
2425
Encore NC Cover
5/05
®
Homeowner's
Installation and

Operating Manual

For use in Europe
30005552 7/11 Rev. 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Encore 2040CE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vermont Castings Encore 2040CE

  • Page 1: Operating Manual

    ® Non-catalytic / catalytic woodburning Stove Model 2040ce Homeowner’s Installation and Operating Manual For use in Europe 2425 Encore NC Cover 5/05 SaFeTy NoTice: iF ThiS appliaNce iS NoT pRopeRly iNSTalleD, opeRaTeD aND MaiN- TaiNeD, a hoUSe FiRe May ReSUlT.
  • Page 2: Table Of Contents

    At MHSC, we share that joy and appreciation for the hearth. We assure you that your cast-iron Vermont Castings stove has been made with the utmost care and will provide you with many years of service.
  • Page 3: Specifications

    Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® Specifications encore Model 2040ce Nominal heat out put ..7.8 - 8.0 kW (34,000 BTU/hr) Width (leg-to-leg) ........685 mm (27”) Minimum flue draught ......12 Pa (0.048” WG) Depth (leg-to-leg)........380 mm (15”) Mean flue gas temp ........ 339° C (642° F) Height to top of flue collar ......635 mm (25”)
  • Page 4: Installation

    Vermont Castings’ stove indicates the stove has performance often results. An Outside Air Adapter Kit for been tested to current standards. The test standard is the Encore is available from your local Vermont Castings EN13240:2001 + A2:2004 for Europe. Clearance and dealer.
  • Page 5 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® what kind of chimney to Use prefabricated chimneys You must connect the Encore to a code-approved masonry These should be an internal diameter of 150 mm (6”) and chimney with a flue liner, to a relined masonry chimney that be of the twin wall insulated construction that has been meets local codes, or to a prefabricated metal chimney.
  • Page 6 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® Single-wall chimney connectors Flue Pipes with a spigot and socket joint should be fitted with the socket facing upwards, to contain condensates • Begin assembly at the flue collar of the stove. Insert the and moisture within the flue.
  • Page 7 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® Chimney Flue Thimble Sleeve Flue Chimney Connector Elbow Flue Liner Keep Slip Pipe sleeve end flush Thimble with flue Standard tile Connector Oval to Round Adapter ST243 Flue Collar Fig. 6 The thimble, made of either ceramic or metal, must be cemented securely in place.
  • Page 8 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® Check These Clearances Flexible Connector * Check These Clearances Mantel Shield Fireplace Adapter Mantel Kit “Positive Con- nection” Seal D E F I A N T This Off ST244a ST245 Fig. 7 In this installation, the chimney connector attaches to Fig.
  • Page 9 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® hearths This appliance must be installed on to hearth that meets the requirements of Part J of the Building Regulations 2000 (Combustion Appliances and Fuel Storage Systems). This can be achieved by ensuring that the hearth is constructed and sized in accordance with the guidelines included in sec- tion 2 of approved document ‘J’.
  • Page 10 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® In addition, furnishings and other combustible materials Minimum rear clearance from combustible walls (e.g. must be kept away from the stove as well. In general, a timber framed or studded walls) 254 mm (10”) mea- distance of 1219 mm (48”) must be maintained between...
  • Page 11 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® at least at least at least 3 x D 3 x D 1.5 x D at least 1.5 x D Fluepipe at least 1.5 x D at least 1.5 x D Air space of at least 12 mm...
  • Page 12: Assembly

    Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® assembly Set Up your Stove Cast iron stoves are heavy, and it will take two to four people to move your Encore into position. Wipe the protective coating of oil from the...
  • Page 13 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® Fan kit installation Air Deflector Air Deflector 1. Attach the fan assembly at the bottom edge of the in- Sheet ner back with two (2) 1/4-20 x 3/4” hex head screws. Metal 2.
  • Page 14 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® installing or Removing catalyst 1. Remove the access cover by gently lifting up and pull- ing out from the bottom edge. (Fig. 21) 2. Remove the inner cover by pulling it straight out. (Fig.
  • Page 15: Operation

    Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® operation The encore controls Two controls regulate the performance of the Encore: a primary air control supplies oxygen for the fire, and a low heat damper directs air flow within the stove to activate and deactivate the catalytic combustor.
  • Page 16 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® combustion system in your Encore work together to pro- use a full load of dry slab wood or scrap wood. For long duce optimum conditions for secondary combustion. burns, use a mix of dry and moderately dry wood.
  • Page 17 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® • caUTioN: The encore will be hot while in operation. Remove the ash pan, making sure to keep it level. keep children, clothing and furniture away. contact • To keep the cover from sliding off and to keep ash from may cause skin burns.
  • Page 18: Maintenance

    If you need to replace the glass, use only the high tempera- dure. ture 5 mm ceramic glass supplied by Vermont Castings. Do not use substitutes. care of the cast iron Surface Removing the glass An occasional dusting with a dry rag will keep the painted cast iron of your Encore looking new.
  • Page 19 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® adjust the Damper as Needed Roller Shoulder Screw The tension on the Encore’s damper is adjustable to com- pensate for compression of the gasket that seals the damper to the upper fireback. To adjust the damper: 1.
  • Page 20: The Chimney System

    Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® all gasketed construction gaskets Other gaskets form seals between all other non-moving parts, but these are not subject to the same wear and deterioration as gaskets on moving parts. It is unlikely...
  • Page 21 If you cannot inspect or clean the chimney yourself, con- aNNUal SpRiNg cleaNiNg: tact your local Vermont Castings dealer or a professional • Disassemble the chimney connector and take it outdoors chimney sweep.
  • Page 22: The Catalytic Element

    Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® Once you have ruled out any other possible causes for a he catalytic element decline in performance, inspect and clean the combustor This wood heater contains a catalytic combustor, which if necessary. Be sure to protect any surface you use for needs periodic inspection and replacement for proper setting the stove parts aside.
  • Page 23 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® 3. If the element is in good condition and clean, re-install it in the stove and replace the refractory inner fireback and access door. Operate the stove in your usual manner for two weeks, in- specting the chimney and the chimney connector frequently during this period.
  • Page 24: Replacement Parts

    Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® 87 27 26 28 73 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. encore Noncatalytic/catalytic woodburning Stove 30005552...
  • Page 25 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® encore Noncatalytic/catalytic woodburning Stove Model item Description part Number item Description part Number 51. Ashdoor Handle (Wood) 1600663 1. Brick Support Bracket 30005279 52. Ashdoor Hinge Rod 30002473 2. Griddle Gasket 1203668 53.
  • Page 26 Encore 2040CE Non-Catalytic / Catalytic Woodburning Stove ® encore Noncatalytic/catalytic woodburning Stove Model 2040 (continued) Shell enamel parts - encore Model 2040 brown part Name classic biscuit bordeaux ebony Majolica 30002387 30003055 30002615 30003075 30004879 Left Side 30002388 30003052 30002613...
  • Page 27: Warranty

    50 % If a defect is noted within the warranty period, the customer should 37 - 48 months contact a Vermont Castings Authorized Dealer or MHSC if the purchase 49 - 60 months was direct with the following information: 61 - 72 months 1.
  • Page 28 MhSc 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...

Table of Contents