CX233 I NSTALLATION AND OPERATION MANUAL CX233 Zone Mixer Installation and operation manual Contents Section Page General description ..............2 Music inputs ................2 2.01 Music inputs..............2 2.02 Gain Control..............2 2.03 Front panel level controls..........2 2.04 Priority................2 Microphone inputs ..............2 3.01 Mic inputs ................2 3.02 Gain Control..............3...
NSTALLATION AND OPERATION MANUAL General Description The CX233 is a versatile multi-source mixer/zoner that can be used with confidence as part of a professional sound system. The impressive performance and flexible routing options together with the remote level control facility make it suitable for a wide range of applications.
600 ohm. 3 pin XLR type connectors are used for all outputs. The nominal output is 0dBu (775mV) but the CX233 can operate satisfactorily with a wide range of signal levels up to a maximum balanced output of +26dBu. If you are connecting any zone output to an unbalanced input see section 9.02 "Unbalanced Mode".
VCA modules. These compact modules utilise a pair of industry standard low distortion VCA's and simply plug into the upper PCB adjacent to the output circuitry. The modules can be retro-fitted but the CX233 would normally be supplied with the modules fitted if specified at the time of ordering.
CX233. When the remote level control facility is being used, it may be desirable to defeat the front panel zone level control on the CX233 and this can be done by configuring an internal jumper.
In certain circumstances, there may be a local authority or fire service requirement to mute the music signals via a fire alarm control panel in an alarm condition. The CX233 provides a facility to attenuate or fully mute the music signals only, by using a fully floating pair of contacts in the control panel which would need to be closed during an alarm condition.
CX233 I NSTALLATION AND OPERATION MANUAL Unbalanced Mode If the zone outputs are required to operate in the unbalanced mode, it is suggested that the unused pin of the XLR connector is not connected. The nominal output signal in this mode is -6dBu and a small amount of extra gain may be required.
CX233 I NSTALLATION AND OPERATION MANUAL General Specifications Power Consumption 25VA Power Requirements 115V ± 5% or 230V ± 5% Fuse Ratings Power T250mA at 115V Power T125mA at 230V Battery T800mA (internal) Width 482.6mm (rack) 432.0mm (free standing) Height 88.0mm (2U)