Troubleshooting - Mitsubishi Electric Mr.Slim PCA-A-KA4 Operation Manual

Indoor unit
Hide thumbs Also See for Mr.Slim PCA-A-KA4:
Table of Contents

Advertisement

Available languages

Available languages

6. Care and Cleaning
► Filter removal
Caution:
• In removing the filter, precautions must be taken to protect your
eyes from dust. Also, if you have to climb up on a stool to do the
job, be careful not to fall.
• When the filter is removed, do not touch the metallic parts inside
the indoor unit, otherwise injury may result.
PKA-A·KA4
A
B
1 Using both hands, pull both the bottom corners of the intake grille
to open the grille, then lift the filter until it clicks at the stop position.
2 Hold the knobs on the filter and pull the filter up, then pull it out
downward.
(Located in two places, on the left and right.)
A Front grille
B Filter

7. Troubleshooting

Having trouble?
Air conditioner does not heat or cool well.
When heating operation starts, warm air does not blow from the indoor
unit soon.
During heating mode, the air conditioner stops before the set room
temperature is reached.
Airflow up/down direction changes during operation or airflow up/down
direction cannot be set.
When the airflow up/down direction is changed, the vanes always move
up and down past the set position before finally stopping at the position.
A flowing water sound or occasional hissing sound is heard.
A cracking or creaking sound is heard.
The room has an unpleasant odor.
A white mist or vapor is emitted from the indoor unit.
Water or vapor is emitted from the outdoor unit.
6
PCA-A·KA4, PCA-A·KA5
C
1 Open the intake grille.
2 Hold the knob on the filter then pull the filter up in the direction of
an arrow. To replace the filter after cleaning, be sure to insert the
filter far enough until it fits into the stopper.
A Filter
B Intake Grille
Here is the solution. (Unit is operating normally.)
 Clean the filter. (Airflow is reduced when the filter is dirty or clogged.)
 Check the temperature adjustment and adjust the set temperature.
 Make sure that there is plenty of space around the outdoor unit. Is the
indoor unit air intake or outlet blocked?
 Has a door or window been left open?
 Warm air does not blow until the indoor unit has sufficiently warmed
up.
 When the outdoor temperature is low and the humidity is high,
frost may form on the outdoor unit. If this occurs, the outdoor unit
performs a defrosting operation. Normal operation should begin after
approximately 10 minutes.
 During cooling mode, the vanes automatically move to the horizontal
(down) position after 1 hour when the down (horizontal) airflow up/
down direction is selected. This is to prevent water from forming and
dripping from the vanes.
 During heating mode, the vanes automatically move to the horizontal
airflow up/down direction when the airflow temperature is low or
during defrosting mode.
 When the airflow up/down direction is changed, the vanes move to the
set position after detecting the base position.
 These sounds can be heard when refrigerant is flowing in the air
conditioner or when the refrigerant flow is changing.
 These sounds can be heard when parts rub against each due to
expansion and contraction from temperature changes.
 The indoor unit draws in air that contains gases produced from the
walls, carpeting, and furniture as well as odors trapped in clothing,
and then blows this air back into the room.
 If the indoor temperature and the humidity are high, this condition may
occur when operation starts.
 During defrosting mode, cool airflow may blow down and appear like a
mist.
 During cooling mode, water may form and drip from the cool pipes
and joints.
 During heating mode, water may form and drip from the heat
exchanger.
 During defrosting mode, water on the heat exchanger evaporates and
water vapor may be emitted.
A
B
D
C Knob
D Stopper

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr.slim pca-a-ka5Mr.slim pka-a-ka4

Table of Contents