Use a Digital Multi Meter for testing and verifying circuits. DO NOT USE A TEST LIGHT, OR "COMPUTER SAFE PROBE" as these can set off air bags or damage vehicle computers. Technical Support (800) 421-3209 or go to http://techservices.codesystems.com 2010 Audiovox Electronics Corporation. All rights reserved.
General Motors VATS bypass, see the following diagram. Use an SPDT relay (not supplied). Ignition 3 output, see the following diagram. Use an SPDT relay (not supplied). Accessory 2/3 output, see the following diagram. Use an SPDT relay (not supplied). 2010 Audiovox Electronics Corporation. All rights reserved.
Page 6
5. Have someone press on the gas pedal slightly as you monitor the meter. If connected to the correct wire, the voltage reading will increase as the engine’s RPM increases. Connect the PURPLE/WHITE wire to the negative side of the vehicle ignition coil or fuel injector. 2010 Audiovox Electronics Corporation. All rights reserved.
Connect the WHITE wire to the parking light output wire. Negative switching Parking Lights: Connect the WHITE/RED wire to a good chassis ground. Connect the WHITE wire to the parking light output wire. 2010 Audiovox Electronics Corporation. All rights reserved.
RUN) position, but not the ACC (Accessory) position. The voltage does not drop out when the key is turned to the START (or CRANK) position. Connect the PINK/WHITE wire to the vehicle’s ignition 2 wire. Programmable output: IGN, ACC, Start. 2010 Audiovox Electronics Corporation. All rights reserved.
This wire will supply a ( - ) 200mA pulse both upon arming the system and upon successful completion of the remote start activation sequence and is typically used to re-lock the vehicle’s doors upon remote start if necessary. 2010 Audiovox Electronics Corporation. All rights reserved.
Please review the wire and location chart to see which type of door lock system is in your vehicle. The most common types are shown in the following diagrams. 2010 Audiovox Electronics Corporation. All rights reserved.
Page 11
Connect the GREEN and BLUE wires shown in the diagram below. Positive Locks: Fused +12 Volt Battery Souce GREEN (-) Lock Output Lock Fused +12 Volt Vehicle Door Lock Battery Souce Control Relays Unlock BLUE (-) Unlock Output 2010 Audiovox Electronics Corporation. All rights reserved.
Page 12
Connect the GREEN and BLUE or BLUE/GREEN wires shown in the diagram below using (2) SPDT relays (not supplied). Multiplex Locks: Ground Fused +12 Volt GREEN (-) Lock Output BLUE (-) Unlock Output Battery Source Resistor Lock Vehicle Door Lock Control Relays Unlock 2010 Audiovox Electronics Corporation. All rights reserved.
Page 13
BLUE wires shown in the diagram below using (2) SPDT relays (not supplied). Fused +12 Volt Battery Source Door Lock GREEN (-) Lock Output Actuator Chassis Ground Fused +12 Volt Battery Source BLUE (-) Unlock Output Chassis Ground 2010 Audiovox Electronics Corporation. All rights reserved.
2 - 4 chirps. NOTE: The system will remain in feature programming mode as long as the ignition is on, there is no time limit. To exit programming turn the IGNITION OFF. 2010 Audiovox Electronics Corporation. All rights reserved.
Within the 7 flash time period, press and hold the button. The system will chirp 1 time indicating the system is now in tachless mode. 2010 Audiovox Electronics Corporation. All rights reserved.
Factory Disarm - Single 1 second pulse with unlock and remote start activation. 2nd Unlock - Same output as unlock with 2nd press of unlock. Start Status - Continuous ( - ) output during the remote start cycle. 2010 Audiovox Electronics Corporation. All rights reserved.
Page 19
3 - Running Lights: Controls the WHITE parking light output wire during remote start. Steady - Parking lights constant during the remote start cycle. Flashing - Parking lights flash at a slow pace during the remote start cycle. 2010 Audiovox Electronics Corporation. All rights reserved.
Page 20
45 Second Delay - Diesel engine, delays the starter output wire for 45 seconds after the ignition has been powered up by the remote start. 2010 Audiovox Electronics Corporation. All rights reserved.
Shut Down Run Time Press and Release 4 times. Extention Ignition ON/OFF, Press and Hold 2 / 3 Hour Start Valet Button, Press Start 4 times Daily Start Timer Press Lock + Start 2010 Audiovox Electronics Corporation. All rights reserved.
To manually enter diagnostics and view the last shutdown, turn the ignition ON and press and release the button. LED FLASHES SHUTDOWN ZONE 3 Flashes Hood Input Brake Input 4 Flashes Remote Start Valet Mode 7 Flashes Tach not learned / Crank Average not learned 2010 Audiovox Electronics Corporation. All rights reserved.
2. This device must accept any interference received, including any interference that may cause undesired operation. Warning! Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 2010 Audiovox Electronics Corporation. All rights reserved.