These safety instructions are to interference when the equipment is operated ensure the long life of your MT105-106/107/109 in a commercial environment. This equipment and to prevent fire and shock hazard. Please read generates, uses, and can radiate radio them carefully and heed all warnings.
T° Operating 10°C-50°C T° Maximum 75°C Humidity 90% non-condensing Multiple MT105-106 cards can be installed in the MTBF (calc.) 50,000 hrs enclosure to provide additional functionality. For example, three cards to handle Component Video. Table 2. MT105-106/109 Mechanical If you need to switch signals use MT105-107.
MULTI-TASKER BLOCK DIAGRAM INSTALLING YOUR MULTI-TASKER™ OPERATION Step 1. Slide the MT105-106/107/109 into an 9.1 RS-232 CONTROL available slot in the Multi-Tasker™ When used in the Multi-Tasker™ Enclosure, the Enclosure in order to connect to the MT105-106/107/109 has many advanced remote bus.
Commands such as [ON], [OFF], and [IO] that Example: end in "S" will be saved into memory. If one MT105-106/107/109 card is in slot #2 of Commands not ending in "S" will still be unit 3. When sending command [VERC2U3], executed but will not be restored when the Multi- Tasker™...
Page 9
Card 2 of Unit 0. Example: 6. [ON] If one MT105-106/107/109 card is in slot #2 of This command enables one or more outputs of a unit 3 with output 1, 2 and 3 ON: single card or group of cards.
Page 10
MULTI-TASKER [ONmGkUiS]: for a group of cards Example: This command enables output "m" for each card [ON1C2U3F]: if path is not set in group "k" of unit "i". [ON1C2U3PF]: if path is set m = card output (m = # from 1-6) 7.
Page 11
MULTI-TASKER [OFFG5U1]: Turns OFF all outputs for each Example: card in group 5 of unit 1. [ON12C6U3P] [OFF…..P]: sets path [ON34C7U3P] [SW] This command will set the path for the output, but it is not active until the switch command is The system will return feedback as OK if the unit executed ( [SW] ).
MULTI-TASKER k = group number (k = # from 1-9) k = group number (k = # from 1-9) i = unit number (i = # from 0-9) i = unit number (i = # from 0-9) Example: member = C1 - C19 (card 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) To group card #1, 2 and 3 as group 5 of unit #1, send the [WRC1C2C3G5U1] command.
592 Apollo street Brea, CA 92821 USA TROUBLESHOOTING GUIDE TEL: 714 990-2300 We have carefully tested and have found no TOLL FREE: 1-800-ALTINEX problems in the supplied MT105-106/107/109; WEB: www.altinex.com however, we would like to offer suggestions for the E-MAIL: solutions@altinex.com...