Sanyo VPC-SX 560EX Service Manual page 19

Color digital camera
Table of Contents

Advertisement

4. AWB adjustment value will appear on the screen.
5. Click the OK.
8. Lens Adjustment
Serial cable
Camera
Preparation:
POWER switch: ON
Adjustment condition:
More than A3 size siemens star chart
Fluorescent light illumination with no flicker
Illumination above the subject should be 400 lux
Adjustment method:
1. Set the siemens star chart 95 cm
comes center of the screen.
2. Double-click on the DscCalDi126.
3. Click the Focus, and click the Yes.
4. Lens adjustment value will appear on the screen.
5. Click the OK.
9. CCD Defect Detect Adjustment
Preparation:
POWER switch: ON (Set the camera mode.)
Adjustment method:
1. Double-click on the DscCalDi126.
2. Select CCD Defect Detection on the LCD "Test", and click
the "Yes".
3. After the adjustment is completed, OK will display.
4. Click the OK.
Approx.
95 cm
3 cm
Siemens
star chart
10 %.
3 cm so that it be-
10. LCD Panel Adjustment
[CA3 board (Side A)]
10-1. LCD H AFC Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. Double-click on the DscCalDi126.
2. Select 0 on the LCD "H AFC".
3. Apply the trigger at CL173, and adjust VR171 so that the
time A from the point where the pulse at CL170 rises until
the position where the video signal at CL173 starts in 0.82
0.1 µsec (for VPC-SX560EX and VPC-SX560E) or 1.5
0.1 µsec (for VPC-SX560).
CL170
CL173
CL170
CL173
– 19 –
VR171
CL170
CL173
CL171
CL172
A
enlargement