PROBLEM
8.
Long off Cycle - Too Warm at Start
9.
Short off Cycle
10. Long or Continuous Operation
11. Short Run Cycle
12. Condensation on Cabinet Exterior
13. Unit will not Deliver Ice Cubes
14. Unit will not Deliver Water
15. Water Delivery Slow
16. Water Accumulating in the
Refrigerator Bottom Area

TROUBLESHOOTING

A. Low ambient temperature
B. Freezer temperature control knob set too warm.
C. Freezer temperature control out of calibration
A. High ambient and/or heavy usage
B. Freezer control knob set too cold.
C. Freezer control out of calibration.
D. Light on constantly
E. Poor door seal
A. High ambient and/or heavy usage
B. Inadequate condenser air flow
C. Freezer temperature set too cold.
D. Freezer temperature control out of calibration.
E. Freezer temperature control relay frozen closed.
F.
Loss of refrigerant or restriction
A. Low ambient and/or light usage
B. Freezer temperature control setting too warm or control out of
calibration
A. High humidity installation (design accepts bead of water on
exterior of cabinet after 4 hours with a 0° to 2°F. (-18° to -17°C.)
freezer food temperature and 38° to 40°F. (3°C to 4°C) refrig-
erator food temperature in 84% R.H. conditions (See example
of typical sweat pattern under above conditions. Fig. 13 )
B. Freezer control set too cold.
C. Freezer control out of calibration
D. Poor door gasket seal.
E. Insulation void.
A. No power to auger drive motor. Check circuitry through ice ac-
tuator switch and upper freezer breaker auger motor switch.
B. Drive Motor open
C. Run Capacitor inoperative.
D. Drive motor tripped out on overload after 90 seconds of con-
tinuous use. Allow three minutes to reset.
E. Nonelectrical malfunctions. Power off for a period of time lets
the cubes refreeze together. No use for a period of time lets the
cubes freeze together. Improperly sealing chute door (check with
flash light). Malfunction in drive train components of bucket
assembly.
A. No power to water dispensing solenoid vase. Check circuitry
through water dispensing switch.
B. Water dispensing solenoid valve coil open
C. Water dispensing switch open
D. Water dispensing arm does not close water dispensing switch.
E. Water line or tank frozen.
F.
Freezer door interlock switch is open.
A. A kink in the tubing may restrict the water flow. Replace the
water line. Flow rate should be 1.7 to 3.5 liter per minute with
inlet pressure from 20 to 120 PSI (1.38 to 8.2 BAR).
A
Leak in the water tank or connection
22