Direct Intake Vent System - Takagi T-M50 ASME Installation Manual And Owner's Manual

On-demand water heater
Hide thumbs Also See for T-M50 ASME:
Table of Contents

Advertisement

This T-M50 water heater may be converted to a direct vent (sealed combustion) appliance by
installing an adapter (Part No. TM-DV50) which will bring all required combustible air from
outside the building. When installing the TM-DV50 conversion kit, please follow all instructions
included with the kit.
The T-M50 must be installed in a location where the proper amount of combustible air
will be available to it at all times without obstructions.
If used as a direct vent appliance, the T-M50 requires a 5" combustible air supply pipe.
The intake pipe must be sealed airtight.
Air supply pipe can be made of ABS, PVC, galvanized steel, corrugated aluminum,
corrugated stainless steel or Category III stainless steel.
Change the dipswitch settings to the direct vent system. (See diagram below)
Sidewall venting is recommended for the direct vent system.
Takagi recommends running the exhaust vent and the intake pipe parallel.
Upper bank of
dipswitches
7-Seg LED
Lower bank of
dipswitches
TM-DV50 Direct Vent
Conversion Kit
TM-DV50 DIRECT VENT
CONVERSION KIT

DIRECT INTAKE VENT SYSTEM

Make sure power to the unit is
turned OFF before changing
the dipswitch settings.
O
N
INTAKE
LOUVER COVER PLATES
- 11 -
The dark square is the direction
the dipswitch should be set to.
1
2
3
4
5
6
Lower Bank of Dipswitches
EXHAUST
7
8