Clearance Dimensions

• This rangetop may be installed directly
adjacent to existing 36" (91.4 cm) high
base cabinets.
IMPORTANT: The top of the side trim
MUST be 3/8" (.95 cm) above the
adjacent base cabinet countertop.
• The rangetop CANNOT be installed
directly adjacent to sidewalls, tall cabinets,
tall appliances, or other side vertical
surfaces above 36" (91.4 cm) high. There
must be a minimum of 6" (15.2 cm) side
clearance from the rangetop to such
combustible surfaces above the 36"
(91.4 cm) counter height.
• Within the 6" (15.2 cm) side clearance
to combustible vertical surfaces above
36" (91.4 cm), the maximum wall cabinet
depth must be 13" (33.0 cm) and wall
cabinets within this 6" (15.2 cm) side
clearance must be 18" (45.7 cm) above
the 36" (91.4 cm) high countertop.
• Wall cabinets above the rangetop must be
a minimum of 42" (106.7 cm) above the
rangetop cooking surface for the full width
of the rangetop. This minimum height
requirement does not apply if a rangetop
hood is installed over the cooking surface.
CAUTION
Note: Based on 24" (61 cm) deep cabinet.
Note: Minimum clearance for back wall is
BURN HAZARD
To avoid risk of personal injury;
0" with backguard or high-shelf.
the use of cabinets for storage
above the appliance may result
Note: If a rangetop hood is installed, wall
in a potential burn hazard. Combustible
cabinets above the rangetop have a different
items may ignite, metallic items may
minimum clearance height.
become hot and cause burns. If a cabinet
storage is to be provided the risk can be
reduced by installing a rangehood that
projects horizontally a minimum 5" (12.7 cm)
beyond the bottom of cabinets.
10
(Proximity to Cabinets)
.
a x
" m
)
c m
1 3
. 0
3 3
(
i n .
" m
)
c m
4 2
6 . 7
6 "
( 1 0
m i
( 1 5
n .
. 2
c m
)
/ 8 "
i n .
8 - 1
)
c m
" m
)
. 6
c m
( 2 0
1 8
. 7
( 4 5
"
3 / 8
)
c m
9 5
( 0 .
Clearance Dimensions
The bottom of a standard hood should be
30" (76.2 cm) min. to 36" (91.4 cm) max.
above the countertop. This would typically
result in the bottom of the hood being
66" (167.6 cm) to 72" (182.9 cm) above the
floor. Refer to the rangetop hood installation
instructions for additional information. These
dimensions provide for safe and efficient
operation of the hood.
6 6
" m
( 1 6
7 . 6
Note: Minimum clearance for
c m
7 2
t o
back wall is 0" with backguard
" m
( 1 8
a x
or high-shelf.
2 . 9
c m
W o
o d
/ C o
m p
O v
o s i
e r l
t e
a y
Wall Installation
"
3 0
)
c m
3 0
6 6
. 2
" m
" m
( 7 6
( 7 6
( 1 6
i n .
i n .
. 2
7 . 6
c m
c m
t o
)
3 6
t o
)
7 2
6 "
" m
" m
m )
( 9 1
( 1 8
a x
. 2 c
a x
. 4
2 . 9
.
.
( 1 5
c m
c m
)
)
Island Installation
11
(Wood/Composite Overlay)
W o
o d
/ C o
m p
O v
o s i
e r l
t e
a y
"
2 4
)
c m
. 0
( 6 1
o r
i n .
"
2 7
)
c m
3 0
)
. 6
" m
( 3 8
( 7 6
i n .
. 2
.
c m
t o
)
3 6
0 "
)
" m
m )
( 9 1
a x
0 c
. 4
(
.
c m
)
Important: This rangetop comes standard
with an Island Trim. There must be a
minimum of 6" (15.2 cm) clearance from
rear of rangetop to a combustible wall.
Clearances from non-combustible
materials are not part of the ANSI Z21.1
scope and are not certified by CSA.
Clearances to non-combustible materials
must be approved by the authority having
jurisdiction.
Note: 6" (15.2 cm) min. with island trim and
combustible rear wall. 0" with island trim
and non-combustible rear wall.