Calibration, Repair, And Technical Support Services - Extech Instruments Extech 380976 User Manual

1φ/3φ 1000 amp true rms power clamp-on
Hide thumbs Also See for Extech 380976:
Table of Contents

Advertisement

1Φ/3Φ Apparent Power (KVA)
Range
60.00KVA (<100A)
600.0KVA (>100A)
Phase Angle (50/60Hz)
Range
-60° ~ 0° ~ +60°
Frequency
Range
40Hz/1KHz
Calibration and Repair Services
Extech offers repair and calibration services for the products we sell. Extech also provides NIST
certification for most products. Call the Customer Service Department for information on calibration
services available for this product. Extech recommends that annual calibrations be performed to
verify meter performance and accuracy.
Technical support: Extension 200; E-mail: support@extech.com
Repair & Returns: Extension 210; E-mail: repair@extech.com
For the latest version of this User Guide, Software updates, and other
up-to-the-minute product information, visit our website: www.extech.com
Extech Instruments Corporation, 285 Bear Hill Road, Waltham, MA 02451
All rights reserved including the right of reproduction in whole or in part in any form.
Resolution
10VA
100VA
Resolution
0.1º
Resolution
0.1Hz
Support line (781) 890-7440
Product specifications subject to change without notice
Copyright © 2007 Extech Instruments Corporation
Accuracy
±(2.5% + 20d)
Accuracy
±6.0º
Accuracy
±(0.5% + 2d)
20
Overload Protection
600VAC/1000AAC
Sensitivity
ACV>100V, ACA>10A
Sensitivity
ACV>5V, ACA>6A