Failure Modes - Metrologic MS1633 FocusBT Installation And User Manual

Bluetooth enabled area imaging bar code scanner
Hide thumbs Also See for MS1633 FocusBT:
Table of Contents

Advertisement

S
O
CANNER
PERATION
Visual Indicators
Steady White
When the scanner successfully reads a bar code it will beep once and the
white LED will turn on indicating data is being transmitted.
After a successful scan, the scanner transmits the data to the host
device. Some communication modes require that the host inform the
scanner when data is ready to be received. If the host is not ready to
accept the information, the scanner's white LED will remain on until the
data can be transmitted.
Alternating Flashing of Blue and White
This indicates the scanner is in configuration mode. A short razzberry tone
indicates that an invalid bar code has been scanned while in this mode.
Flashing Blue
The blue LED will flash if the trigger is pressed while the scanner is in the
in-stand presentation mode. The blue LED will stop flashing after a brief
period of time.
The operation range of Bluetooth communication is approximately
10 meters between the scanner and host system. If the unit is out of range,
the communication link will break, the blue LED will start to flash, and the unit
will emit a double razz tone. The blue LED will continue to blink for 30
seconds while the unit is out of rage. If RangeGate or Inventory mode are not
enabled, the scanner will enter sleep mode to conserve battery power after 30
seconds.

Failure Modes

Long Razzberry Tone – During Power Up
Failed to initialize or configure the scanner. If the scanner does not respond
after reprogramming, return the scanner for repair.
Short Razzberry Tone – During Scanning
An Invalid bar code has been scanned when in configuration mode or the
trigger has been pulled too fast.