  • Page 1 UL-ES-3V52-WH 04 (rev 1) OWNER'S MANUAL MANUAL DEL USUARIO Vector N.W. : 5.9 KGS Item # / Ítem No.: Finish / Acabado: G.W. : 7.5 KGS 78179 Titanium / Titanio...
  • Page 2: Safety Tips

    UL-ES-3V52-WH 04 (rev 1) SAFETY TIPS OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT", AND USE THE OUTLET SCREWS PROVIDED WITH THE OUTLET BOX. MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED.
  • Page 3: Consejos De Seguridad

    UL-ES-3V52-WH 04 (rev 1) CONSEJOS DE SEGURIDAD HAGA LO SIGUIENTE: LEA Y GUARDE ESTAS INSTRUCCIONES ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O LESIONES PERSONALES, MONTE EL VENTILADOR EN UNA CAJA DE EMBUTIR ROTULADA “ADECUADA PARA VENTILADORES”, Y UTILICE LOS TORNILLOS DE MONTAJE INCLUIDOS CON LA CAJA DE EMBUTIR. LA MAYORÍA DE LAS CAJAS DE EMBUTIR UTILIZADAS NORMALMENTE PARA ARTEFACTOS DE ILUMINACIÓN NO SON ADECUADAS PARA VENTILADORES Y DEBERÍAN SER REEMPLAZADAS.
  • Page 4 UL-ES-3V52-WH 04 (rev 1) FEATURES CARACTERÍSTICAS DOWNROD VAULTED CEILING INSTALLATION INSTALLATION FLUSH MOUNT INSTALLATION INSTALACIÓN CON INSTALACIÓN PARA INSTALACIÓN AL RAS VARILLA VERTICAL CIELORRASOS ABOVEDADOS COMBO-BLADE Combo-Blades feature two high quality finishes on one blade. Select the one that best complements your decor, or change the style with just a flip of the blade. For low ceilings For normal ceilings May require a longer downrod...
  • Page 5: Preparing For Installation

    UL-ES-3V52-WH 04 (rev 1) PREPARING FOR INSTALLATION ANTES DE LA INSTALACIÓN Use metal outlet box suitable for fan support (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural ceiling member (a loose box will cause the fan to wobble).
  • Page 6: Mounting Bracket Installation

    UL-ES-3V52-WH 04 (rev 1) MOUNTING BRACKET INSTALLATION INSTALACIÓN CON SOPORTE DE MONTAJE Remove the screws and star washers from the two mating holes (1) on the canopy. Loosen (do not remove) the screws in the mating slots (2) on the canopy. Rotate the mounting bracket counter-clockwise and remove from the canopy.
  • Page 7: Blade Installation

    UL-ES-3V52-WH 04 (rev 1) MOUNTING BRACKET INSTALLATION BLADE INSTALLATION INSTALACIÓN CON SOPORTE INSTALACIÓN DE LAS PALETAS DE MONTAJE Install mounting bracket to outlet box in ceiling using the screws and Install blade to blade holder using three screws, nuts and fabric washers washers provided with the outlet box.
  • Page 8: Mounting Options

    UL-ES-3V52-WH 04 (rev 1) BLADE INSTALLATION MOUNTING OPTIONS INSTALACIÓN DE LAS PALETAS OPCIONES DE MONTAJE Choose a MOUNTING OPTION Elija una OPCIÓN DE MONTAJE FLUSH MOUNT OPTION If flush mount option is selected, proceed to page 9, step 8. OPCIÓN DE INSTALACIÓN AL RAS Si elige la opción de montaje al ras, proceda a la página 9, paso 8.
  • Page 9 UL-ES-3V52-WH 04 (rev 1) FLUSH MOUNT OPTION OPCIÓN DE INSTALACIÓN AL RAS For flush mount option, raise fan assembly and place onto hook from mounting bracket into a closed hole on the canopy. This will allow for hands free wiring. Guide motor wires through the base of the canopy as shown and attach canopy PROCEED DIRECTLY TO PAGE 14 FOR WIRING OPTIONS.
  • Page 10 UL-ES-3V52-WH 04 (rev 1) EXTENDED DOWNROD OPTION NORMAL DOWNROD OPTION OPCIÓN CON VARILLA VERTICAL OPCIÓN CON VARILLA PARA CIELORRASO NORMAL VERTICAL MÁS LARGA Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yoke and downrod.
  • Page 11 UL-ES-3V52-WH 04 (rev 1) EXTENDED DOWNROD OPTION OPCIÓN CON VARILLA VERTICAL MÁS LARGA Re-install pin into extended downrod, and slide downrod ball up to the top of the downrod. Re-install set screw to secure ball to downrod. Note: Some extended downrods have a pre-drilled set-screw hole. If a pre-drilled hole is present in the extended downrod, tighten the set screw into the pre-drilled hole in the extended downrod.
  • Page 12 UL-ES-3V52-WH 04 (rev 1) EXTENDED DOWNROD OPTION OPCIÓN CON VARILLA VERTICAL MÁS LARGA Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yoke and downrod. Insert clamp pin (2) into cross pin until it snaps into place. Tighten set screws (3) in yoke. Pase los hilos conductores del motor a través de la varilla vertical/conjunto del dosel e inserte la varilla vertical en la horquilla de la misma.
  • Page 13 UL-ES-3V52-WH 04 (rev 1) MOUNTING MONTAJE Carefully lift fan assembly onto mounting bracket. Rotate fan until notch on downrod ball (1) engages the ridge on the mounting bracket (2). This will allow for hands free wiring. With bracket holding fan assembly, make electrical connections using the Levante con cuidado el conjunto del ventilador hasta el soporte de montaje.
  • Page 14 UL-ES-3V52-WH 04 (rev 1) WIRING OPTIONS OPCIÓN DE CABLEADO PULL CHAIN WIRING OPTION WALL CONTROL WIRING OPTION From Fan: From House: From Fan: From House: White (common) White (common) Wall Control White (common) (connect) White (common) (connect) Black (hot) Black (hot) (connect) Black (hot) Fan Switch (hot)
  • Page 15 UL-ES-3V52-WH 04 (rev 1) SECURE TO CEILING SECURE TO CEILING SECURE TO CEILING ASEGURE EL VENTILADOR AL CIELORRASO ASEGURE EL VENTILADOR AL CIELORRASO ASEGURE EL VENTILADOR AL CIELORRASO For flush mount fans, carefully lift fan from the mounting bracket, making sure not to break any wire connections. For downrod fans, slide the canopy up to the mounting bracket.
  • Page 16: Light Fixture Installation

    UL-ES-3V52-WH 04 (rev 1) LIGHT FIXTURE INSTALLATION INSTALACIÓN DEL ARTEFACTO LUMINOSO 10 cm Install light bulbs (not included). Find the wire plugs from the light kit and from the Warning: motor and slide together. Connect the blue wire from 1. Do not allow spot light heads to face each other. the switch housing, to the black wire from the light kit, Attach light kit to the switch housing using three 2.
  • Page 17 UL-ES-3V52-WH 04 (rev 1) Assemble decorative fob and extension chains from hardware bag to fan pull chains by inserting end of chain into chain coupling. Confirm chains are held by lightly pulling both chains in coupling. Sujetar las cadenas largas de tiro con las piezas finales correspondientes, a las cadenas del ventilador, introduciendo el extremo de la cadena larga en la pieza de unión.
  • Page 18: Operation And Maintenance

    UL-ES-3V52-WH 04 (rev 1) OPERATION AND MAINTENANCE Operation Turn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off. Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on.
  • Page 19: Operación Y Mantenimiento

    UL-ES-3V52-WH 04 (rev 1) OPERACIÓN Y MANTENIMIENTO Operación Encienda el ventilador y verifique su funcionamiento. La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera: 1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado. Las velocidades para clima cálido o frío dependen de factores como el tamaño de la habitación, la altura del ventilador, el número de ventiladores, etc.
  • Page 20: Troubleshooting Guide

    UL-ES-3V52-WH 04 (rev 1) If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these TROUBLESHOOTING GUIDE installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot be remedied, please consult with your authorized electrician and do not attempt any electrical repairs yourself.
  • Page 21: Guía Para Solucionar Problemas

    UL-ES-3V52-WH 04 (rev 1) Si tiene dificultades para hacer funcionar su nuevo ventilador, podría ser a causa del armado, instalación o GUÍA PARA SOLUCIONAR PROBLEMAS cableado incorrectos. En algunos casos, estos errores de instalación podrían ser confundidos con defectos. Si experimenta alguna falla, consulte esta guía para solucionar problemas.
  • Page 22 UL-ES-3V52-WH 04 (rev 1)
  • Page 23 UL-ES-3V52-WH 04 (rev 1) PARTS LIST LISTA DE REPUESTOS Description 1 ....Mounting Bracket 2 ....Blade Bracket 3 .
  • Page 24 Philadelphia, PA 19154 U.S.A. Philadelphia, PA 19154 U.S.A. Westinghouse Lighting Corporation, Westinghouse Lighting Corporation, a Westinghouse Electric Corporation licensee titular de la licencia de Westinghouse Electric Corporation is a registered trademark of es una marca registrada de Westinghouse Electric Corporation Westinghouse Electric Corporation...