11

INSTALL HANDLES

LEVER HANDLE
Turn HANDLE STEM (1) to "OFF" position.
Place the HANDLE ADAPTER (2) on the HANDLE STEM (1). Install the
ADAPTER SCREW (3) and tighten securely.
Position LEVER HANDLE (4) and place on ADAPTER (2). Install the
HANDLE SCREW (5) and tighten securely.
12
TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Operate both HANDLES (1) to flush water
lines thoroughly.
Rotate TRANSFER VALVE (5) from rim wash to
spray several times to check operation.
13
CHECK DRAIN CONNECTIONS
Pull up POP-UP KNOB (3) and fill Sink with water. Check
that DRAIN STOPPER (4) makes a good seal and retains
water in Bidet. If STOPPER (4) does not seal properly,
please refer to "Troubleshooting Guide" in these instructions.
Push POP-UP KNOB (3) down and check all drain
connections and "P" trap for leaks.
if necessary.
14
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT
CLEAN WITH CLEAR WATER. DRY
WITH A SOFT COTTON FLANNEL
CLOTH.
DO NOT: DO NOT CLEAN THE
PRODUCT WITH SOAPS, ACID,
POLISH, ABRASIVES, HARSH
CLEANERS, OR A CLOTH WITH
A COARSE SURFACE.
OUTLINE OF BIDET
Tighten
2
15
SERVICE
To change direction of handle
rotation, proceed as follows:
Turn VALVE to OFF position.
Loosen HANDLE SCREW (1) .
Pull HANDLE (2) off ADAPTER (4). Loosen ADAPTER
SCREW (3) and pull off ADAPTER (4).
Remove SPRING CLIP (7). Lift STOP WASHER (5),
turn 90° and replace. Replace SPRING CLIP (7).
Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).
Tighten HANDLE SCREW (1).
If spout drips, operate handles several
times from OFF to ON position. Do not
force - handles turn only 90˚.
4
4
5
3
2
1
3
1
4
1
2
SPRAY
1
2
3
4
90˚
5
6
7
M 9 6 8 6 7 7 R e v . 1 . 1