V-Tec DT591 User Manual

V-Tec DT591 User Manual

2 -wire intercom system
Hide thumbs Also See for DT591:

Advertisement

2 -Wire Intercom System
DT591/592 User Manual
DT591
DT592
DT-ENG-591/592-V1 100S503

Advertisement

Table of Contents
loading

Summary of Contents for V-Tec DT591

  • Page 1 2 -Wire Intercom System DT591/592 User Manual DT591 DT592 DT-ENG-591/592-V1 100S503...
  • Page 2: Table Of Contents

    CONTENTS 1.Parts and Functions..................... 1 2.Terminal Descriptions ..................1 3.Specifications ...................... 2 4.Mounting ......................2 4.1 Mounting Without Rainy Cover ..............2 4.2 Mounting With Rainy Cover ................3 4.3 Placing Name Label ..................3 4.4 Adjusting Camera Angle ................4 5.System Wiring and Connections .................
  • Page 3: Parts And Functions

    1.Parts and Functions Camera Lens Night View LED Speaker Nameplate  Call Button Microphone Rainy Cover 90 mm 23 mm Note: DT592 has two call buttons. 2.Terminal Descriptions 1 2 3 Lock Control Jumper Doorstation Code DIP MIC adjustment SPK adjustment Main Connect Port S 2 + S - P L S 1 +...
  • Page 4: Specifications

    • To select the lock type: see 5.2.1 , 5.2.2 Lock Control Jumper: • Total 4 doorstations can be supported,see 6.1 Doorstation Code DIP: • To connect the bus line and the electronic locks. Main Connect Port: BUS: Connect to the bus line, no polarity. •...
  • Page 5: Mounting With Rainy Cover

    4.2 Mounting With Rainy Cover 160-165cm 4.3 Placing Name Label Move the plastic cover away to open the transparent name label cover, insert a name paper, then put the plastic cover back to the panel. name label...
  • Page 6: Adjusting Camera Angle

    4.4 Adjusting Camera Angle use a screwdriver to loosen the screw and then adjust the angle of the camera ,then fix the screw. 5.System Wiring and Connections 5.1 Basic Connection monitor L1 L2 PL S1+ S2+ S-...
  • Page 7: Electric Lock Connection

    5.2 Electric Lock Connection 5.2.1 Door Lock Controlled with Internal Power Note: Electronic lock of Power-on-to-unlock type should be used. The door lock is limited to 12V, and holding current must be less than 250mA. The door lock control is not timed from Exit Button(EB) Parameter of Monitro must be set to 0 (by default) Unlock Mode connect one lock...
  • Page 8: How To Setup The Unlock Parameter In Monitor

    MENU button to enter next to change the value page. of the item.select Exit item,press MENU button to save the settings automatically. Note: 1.must connect DT591/592 completely before setting 2.the parameter will be saved in doorstation automatically,so you need only set on one monitor...
  • Page 9: Multi Doorstations Connection

    5.3 Multi Doorstations Connection monitors DBC4 A B C D 85~260VAC 4# Camera 3# Camera 2# Camera 1# Camera ID=11 ID=01 ID=10 ID=00 L1 L2 PL S1+ S2+ S- L1 L2 PL S1+ S2+ S- L1 L2 PL S1+ S2+ S- L1 L2 PL S1+ S2+ S-...
  • Page 10: Multi Monitors Connection

    5.4 Multi Monitors Connection 5.4.1 Basic IN-OUT Wiring Mode monitor 3 4 5 6 Code=15, DIP-6=on monitor 3 4 5 6 Code=14, DIP-6=off monitor 3 4 5 6 Code=0, DIP-6=off 85~260AC ID=00...
  • Page 11: With Dbc-4 Wiring Mode

    5.4.2 With DBC-4 Wiring Mode monitor monitor 3 4 5 6 3 4 5 6 Code=14, DIP-6=on Code=15, DIP-6=on monitor monitor 3 4 5 6 3 4 5 6 Code=12, DIP-6=on Code=13, DIP-6=on monitor monitor 3 4 5 6 3 4 5 6 Code=2, DIP-6=on Code=3, DIP-6=on monitor...
  • Page 12: Setup

    6.Setup ON(1) OFF(0) 6.1 DIP Switches Settings of Doorstation Total 2 bits on the DIP switches can be configured.The switches can be modified etther before or after installation. Bit state Descriptions Default setting, ID = 0(00), set to the first Door Station. ID = 1(10), set to the second Door Station.
  • Page 13 Bit-1 to Bit-5 are used to User Code setting. The value is from 0 to 31, which have 32 different codes . Bit state User Code Bit state User Code Bit state User Code Code=0 Code=11 Code=22 3 4 5 3 4 5 3 4 5 Code=1...
  • Page 14: Notices

    6.3 Notices Name Discription Useage Power supply,85~260Vac input,24Vdc/3A output,10 Connect with multi doorstations or multi PS5-24V DIN modeules monitors(up to 2 or above) Power supply,85~260Vac input,24Vdc/1A output,for Connect with one doorstation and one PS4-24V basic kit only,4 DIN modules monitor(DT16 can be connected two) -12-...
  • Page 15: Cables Requirements

    7.Cables Requirements The maximum distance of the wiring is limited in the DT system. Using different cables may also effect the maximum distance the system can reach. The farest monitor monitor with two or four monitors monitor monitor DBC/DBC-4 When Monitor quantity < 20 Cable Usage Twisted cable 2x0.75 mm Twisted cable 2x1 mm...
  • Page 16 The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved. -14-...

This manual is also suitable for:

Dt592