1.Parts and Functions Camera Lens Night View LED Speaker Nameplate Call Button Microphone Rainy Cover 90 mm 23 mm Note: DT592 has two call buttons. 2.Terminal Descriptions 1 2 3 Lock Control Jumper Doorstation Code DIP MIC adjustment SPK adjustment Main Connect Port S 2 + S - P L S 1 +...
• To select the lock type: see 5.2.1 , 5.2.2 Lock Control Jumper: • Total 4 doorstations can be supported,see 6.1 Doorstation Code DIP: • To connect the bus line and the electronic locks. Main Connect Port: • BUS: Connect to the bus line, no polarity. •...
4.2 Mounting With Rainy Cover 160-165cm 4.3 Placing Name Label Move the plastic cover away to open the transparent name label cover, insert a name paper, then put the plastic cover back to the panel. name label...
4.4 Adjusting Camera Angle use a screwdriver to loosen the screw and then adjust the angle of the camera ,then fix the screw. 5.System Wiring and Connections 5.1 Basic Connection BUS(IM) BUS(DS) L1 L2 PL S1+ S2+ S- Doorbell Button Switch...
5.2 Electric Lock Connection 5.2.1 Door Lock Controlled with Internal Power Note: Electronic lock of Power-on-to-unlock type should be used. The door lock is limited to 12V, and holding current must be less than 250mA. The door lock control is not timed from Exit Button(EB). Parameter of Monitor must be set to 0 (by default).
2s. be shown. Note: 1.must connect DT591/592 correctly before setting. 2.the parameter will be saved in DT591/592 automatically,so you need only set on one monitor. 3.Here we take DT47M(the monitor) for example, please refer to the corresponding user manual.
5.4.2 With DBC4A Wiring Mode Impedance Code=15 Code=14 OFF ON switch Code=13 Code=12 Code=3 Code=2 Impedance OFF ON switch Code=1 Code=0 100~240VAC BUS(IM) BUS(DS) ID=00 NOTE:Here we take DT47M(the monitor) for example.
6.Setup ON(1) OFF(0) 6.1 DIP Switches Settings of Doorstation Total 2 bits on the DIP switches can be configured.The switches can be modified either before or after installation. Bit state Descriptions Default setting, ID = 0(00), set to the first Door Station. ID = 1(10), set to the second Door Station.
Page 13
1)Power-on within 5 seconds; Press and hold "B" button for 3 2)Press and hold "B" button for 3 seconds, it will enter the state of seconds, it will enter the setting the ringtone mode setting. state of prepare. Indicator Buzzer Indicator Buzzer beep+,beep...
6.3 Unlock Time Settings The unlock time can be set to 1~30 seconds. The default is 1s. 1)Power-on within 5 seconds; Press and hold "A" button for 3 2)Press and hold "B" button for 3 seconds, it will enter the state of seconds, it will enter the setting the unlock time setting.
7.Cables Requirements The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance which the system can reach. The farest monitor monitor with two or four monitors monitor monitor DBC4A 100~240VAC When Monitor quantity <...
Page 16
The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.