Table 5: SCSI Port Error Log Codes (Continued)
0x10
Offset
0xE3
0xE4
0xE5
0xE6
0xE7
0xE8
0xE9
0xEB
0xEC
0xED
0xEF
0xF1
0xF2
0xF3
0xF4
0xF5
AB232A PCI-X Host Bus Adapter Installation Guide
Explanation
Mailbox rsp err
HBA not ready after init
Requested loop but link =
PT–PT
Mailbox int. but cmd not
complete
SRB already queued to ring
RESTART failed
PORT BYPASS (LPB)
received
Unknown IOCB cmd rsp
Uncached extension alloc.
error
Link down @ boot time
(30 sec)
Too many interrupts at
initial boot
LinkUp error; LP8 down,
driver up
LinkUp w/ illegal or corrupt
RPI
DeQueue
ring->iotcmd.head
HBA reset
PCP_IXXX_CR IOCB rsp
err
0x11 to 0x13 Further Information
0x11 = command, 12–13 =
mbxstatus
Status register bytes 1–3 in event
11–13
0x11 = MB cmd, 12–13 = mbxstatus
0x11 = 15:8 = cmd field
0x11 = parameter field, 12 = IOCB
cmd
0x11 = parameter field, 12 = IOCB
cmd
0x11 = caller ID
0x11 = coded reason for reset:
Bit 0 = IOCB requeue; bit 1 = readla
retry
Bit 2 = initlink retry; bit 3 = rstbus retry
Bit 4 = mailbox time-out
0x11 = cmdstat, 12 = parm err, 13 =
ALPA