P S - P R O E I I / P E I I - P O W E R C O N D I T I O N E R / S E Q U E N C E R
insured. We suggest that you save the original
packaging and use it to ship the product for
servicing. Also, please enclose a note with your
name, address, phone number and a description
of the problem.
NOTE: All equipment being returned for repair
must have a Return Authorization (RA) Number.
To get an RA Number, please call the Furman
Service Department, (707) 763-1010, Ext. 120 or
121, between 8 am and 5 pm U.S. Pacific Time.
Please display your RA Number prominently on
the front of all packages.
PS-PRO E II / PE II SPECIFICATIONS
Current Rating:
16 Amps
Input Voltage:
180 to 280 VAC without damage
Delay Intervals:
Total elapsed ON or OFF delay time adjustable
from 1-60 seconds, with a single trimpot
ON Sequence:
-Delay 1 outlets go on immediately with switch.
-Delays between outlets 1 and 2, and 2 and 3,
adjustable from 1-60 seconds each
OFF Sequence:
-Delay 3 outlets go off immediately with switch.
-Delays between outlets 3 and 2, and 2 and 1,
same as ON delays
Remote Switch:
Screw terminals, 2 for switch, 2 additional for
optional LED (22 ga. minimum)
Spike Protection Modes:
Line to neutral, zero ground leakage
376 Vpk (266 VAC RMS)
Spike Clamping Voltage:
Response Time:
1 nanosecond
Maximum Surge Current:
6,500 amps
Dimensions:
1.75" H x 19" W x 10.5" D.
Weight:
12 lbs.
Construction:
Steel chassis, .125" brushed and black
anodized aluminum front panel; glass epoxy
printed circuit boards
Power Consumption:
11 watts
Safety Agency Listings:
CE
280V HI, 150V LO
Over Voltage Shutdown:
220/240V Versions (units with "E" suffix only) are
Optional:
intended for use in countries with nominal 220 to
240 volt AC mains. Their rear panel outlets use
internationally accepted IEC-320 connectors.
031605-D
Furman Sound, Inc.
Furman Sound, Inc.
1997 South McDowell Blvd.
1997 South McDowell Blvd.
Petaluma, California 94954-6919 USA
Petaluma, California 94954-6919 USA
Phone: 707-763-1010 Fax: 707-763-1310
Phone: 707-763-1010 Fax: 707-763-1310
Web: www.furmansound.com
Web: www.furmansound.com
E-mail: info@furmansound.com
E-mail: info@furmansound.com
P S - P R O E I I / P E I I - P O W E R C O N D I T I O N E R / S E Q U E N C E R

Advertisement

loading

Summary of Contents for Furman PS-PRO E II

  • Page 1 NOTE: All equipment being returned for repair must have a Return Authorization (RA) Number. To get an RA Number, please call the Furman Service Department, (707) 763-1010, Ext. 120 or 121, between 8 am and 5 pm U.S. Pacific Time.
  • Page 2  cord to Purchaser will be paid by Manufacturer. The PS-PRO E II / PE II is controlled by a front panel key-operated switch to provide security S E RV I C E Three year limited warranty THE FOREGOING IS IN LIEU OF ALL OTHER ...
  • Page 3 AC line, making it the most ad- at the PS-PRO E II / PE II’s outlets. If it is high Dangerous high voltages are present inside If multiple PS-PRO E II / PE II’s are controlled by...
  • Page 4: Momentary Mode

    I N S TA L L AT I O N feat the ground or change the polarization REM to GND = ON (jumper plugs installed on The PS-PRO E II / PE II has “memory” — it of the power plug. JMP1 and JMP4)
  • Page 5: Local Control

    Reattach the top cover. NOTE: If the PS-PRO E II / PE II is to be used location. When more than one location is required, between Delay 2 and Delay 3. For example, if...
  • Page 6: Front Panel

    CIRCUIT BREAKER: The overall ca pac i ty of the as the Furman GN-LED or GN-I). Simply slide the the PS-PRO E II / PE II, this in di ca tor will be lit if the to the rear pan el ter mi nals.