Maintaining the machine
8.13

Adjusting stripper

The strippers must be reset or renewed in case of wear.
8.14

Servicing the battery

1) Loosen all three screws on the stripper
► The distance from stripper to drum must be at least 2 cm.
2) Tighten bolts again.
AS
The battery is located underneath the operating panel. It is maintenance-free
according to EN/DIN. That means it that during normal operating temperatures
and correct controller voltage no water must be refilled. Water is used up in the
case of deviation from the standard conditions. The following among others is
considered as a deviation from normal conditions:
High outside temperatures
Demanding use of the machine
Continuous operation on upward gradients and downward gradients within
the extreme range (just below the maximum gradeability).
It is advisable to check the water level of the battery in regular intervals. The service
life is reduced substantially, if the battery is operated with a too low water level.
The battery terminals and cable clips must in particular be cleaned regularly and
then generously greased with petroleum jelly.
– 96 –
NOTE
AS
and push stripper toward the drum.
RX 1510-C/-I/-CI