RX 1510-C/-I/-CI
5.

Start-up

5.1

Safety instructions

5.2

Examination before start-up

5.2.1
Only qualified and appropriately trained specialised personnel, with a minimum
age of 18 years, may operate the machine. Persons acting under the influence of
drugs, medicines or alcohol may not operate the machine.
Before putting the machine into service every day or before a long work period,
the following checks must be performed. The safety regulations must be observed
hereby.
The following must be checked:
The function of all safety equipment
Whether the transport protection has been removed
All bolt connections for firm fit
Fuel tank and fuel lines for leaktightness
Machine and engine for damages
Function of the control elements
Function of the steering system
Hydraulic system for leaktightness

Checking hydraulic oil level

The sight glass for the examination of the hydraulic oil level is located under the
operating panel. The fill level should be within the sight glass.