Download Print this page
American Standard Swan 6011 Installation Instructions
American Standard Swan 6011 Installation Instructions

American Standard Swan 6011 Installation Instructions

In wall pressure balancing bath and shower sets

Advertisement

Quick Links

SWAN
IN WALL PRESSURE BALANCING
BATH AND SHOWER SETS
Thank you for selecting American-Standard...the benchmark of fine
quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these
instructions carefully before you begin.
ROUGHING-IN DIMENSIONS
To assure proper positioning in relation to wall,
note roughing-in dimensions.
FINISHED WALL
4" REF.
5-1/2" REF.
74" FOR HEAD
CLEARANCE
18" OPTIONAL
1-1/2"
MIN.
SLIP-ON
SPOUT
5" REF.
TOP OF TUB RIM
BOTTOM OF TUB
1
ROUGHING-IN
When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS (IF PRESENT). When finished soldering,
NOTE
flush valve body, replace cartridges, check stops (if present) and plaster guard to continue installation. Use thread
sealant or Teflon tape on threaded connections.
See Roughing-in diagram before starting.
Connections are:
1/2" female NPT for threaded inlets
Connect RISER PIPE (1) to MANIFOLD (2)
top outlet marked "SHR".
Connect TUB FILLER PIPE (3) at bottom
outlet marked "TUB".
For proper positioning the finished wall
must be within side wall of PLASTER
GUARD (4).
1/2" NPT
1-5/8"
to
3-1/4"
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 80''
7-1/8"
4"
1/2" COPPER
CAUTION
Turn off water at main supply.
If the valve is installed on a fiberglass
or other thin wall application, the
PLASTER GUARD (4) can be used as a support.
Cut a 4" dia. hole in the shower stall.
Drill two additional 1" holes to allow access
to the stops.
Remove PLASTER GUARD (4), rotate 90˚
so that indicated screw holes fit MANIFOLD (2).
Push CAP on valve, place ESCUTCHEON on and
attach with screws.
Connect hot and cold water supplies.
Cap off shower pipe (5) and tub filler pipe (6).
For support, use pipe BRACES (7) secured to wooden braces.
With valve turned off, turn on water supplies. Check for leaks.
Installation
Instructions
6011
6012
Required Tools
Phillips Screwdriver
Tubing Cutter
Plumbers' Putty or Caulking
INLETS 1/2" NPT
3-3/8"
3-3/8"
OUTLETS
1/2" NPT
THREADED INLETS
Certified to comply with ANSI A112.18.1
Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
OUTLETS
1/2" NPT
5-7/8"
3-3/8"
THREADED INLETS (STOPS)
1
COLD
2
HOT
3
M 9 6 8 4 6 2 S - O
INLETS
1/2" NPT
5
7
4
6

Advertisement

loading

Summary of Contents for American Standard Swan 6011

  • Page 1 SWAN IN WALL PRESSURE BALANCING BATH AND SHOWER SETS Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. ROUGHING-IN DIMENSIONS To assure proper positioning in relation to wall, note roughing-in dimensions.
  • Page 2 INSTALL TRIM CAUTION: Protect finish on SHOWER ARM, SHOWER HEAD and TUB SPOUT when installing. When finished tiling the wall, remove PLASTER GUARD (A) and turn off water supply. Push CAP (1) over VALVE CARTRIDGE (2). Mount ESCUTCHEON (3) and gasket to valve body with SCREWS (4). Remove PIPE CAP (5) from shower pipe.
  • Page 3 TO GAIN ACCESS TO VALVE FOR SERVICING Remove handle SET SCREW, remove HANDLE, unscrew HANDLE SCREW and remove ADAPTER. Remove two SCREWS holding ESCUTCHEON and remove ESCUTCHEON. Remove COVER by pulling straight out. Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve. VALVE LEAKS WHEN SHUT OFF Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2).
  • Page 4 M962304-YYY0A SHOWER ARM AND ESCUTCHEON M952100-0070A PRESSURE BALANCING UNIT M961854-0070A FIXATION RING WITH SCREWS 027816-0070A 1/2" NPT PLUG A954440-0070A CARTRIDGE 023603-0070A CARTRIDGE SCREWS M909732-YYY0A SPOUT ESCUTCHEON BATH AND SHOWER SETS M953530-YYY0A SHOWER HEAD Replace the "YYY" with appropriate finish code CHROME SATIN A923611-0070A...

This manual is also suitable for:

Swan 6012