Clocking

Synchronising to source
Manual part no: DOC136954 iss 2B1
Contact
on + 44 1799 531 999
dCS
(inside the UK replace + 44 with 0)
The sample clock quality significantly determines the performance of a DAC.
The highest quality clocks that are available are crystals, so we use these. The
dCS 954 uses one of two on-board voltage controlled crystal oscillators (VCXOs)
as a clock source – one for 48 kS/s related outputs and one for 44.1 kS/s
related outputs. When the unit is slaved to an external source, the appropriate
VCXO is selected and synchronised to this by a phase locked loop (PLL). The
PLL is of a special narrow bandwidth type, that provides a high degree of "clock
cleaning" - but even so, signal quality may degrade if particularly poor source
clocks are used. A consequence of the narrow bandwidth is that it takes quite a
long time for the PLL to lock to a new clock frequency – of the order of 2
seconds. The PLL uses DSP assistance to keep this time acceptable.
Pull in range
Lock in time
The PLL is very robust, and will lock to very poor signals if necessary. Data is
decoded using a much wider band (faster) PLL, so AES3 type low frequency
jitter on the input clock can be handled, and will be cleaned.
If you need to synchronise several items of digital equipment, we recommend
using a dCS 992 Master Clock.
There is a further discussion of some types of timing error in section
PLL bandwidths"
on page 68.
Manual for Standard Software Version 1.5x
-
> ± 300 ppm about nominal frequency
< 2 seconds for most situations
Page 39
June 2000
"Jitter and
file 135954ma2b1.pdf available from website
email to: more@dcsltd.co.uk
web site: www.dcsltd.co.uk