Duty Cycle
Duty Cycle is the equipment specification which defines the number of minutes
within a 10 minute period that a piece of equipment can safely operate.
This plasma cutter has a 60% duty cycle at 40 Amps, which means that it may be used only
6 minutes at 40 Amps out of any 10 minute period, and must be rested the remaining 4 minutes.
CAUTION: Failure to observe the duty cycle limitations of this Plasma Cutter
can easily damage this equipment, and will void the warranty.
SKU 95136
Rated Input
240V~, 50/60Hz, 19.2A
60%
Rated Duty Cycle
80%
100%
Air Requirements
3.5 CFM @ 60-80 PSI
Power Switch
Rocker Type
Weight
49.6 lb.
Cutting Current
15-40 A
Cutting Thickness
1/2" Mild Steel Maximum
Arc Striking System
Pilot Arc
Unit Size
20" L x 8-1/8" W x 14-3/8" H
Air Inlet
1/4" - 18 NPT
For technical questions, please call 1-800-444-3353.
@
40 A
@
34.6 A
@
31 A