Zanussi ZCG55 User Manual page 21

Cooker
Table of Contents

Advertisement

Important! Use flexible tubing, which comply
with BS.669 current edition.
A
B
C
Warning! The gas bayonet must be in
mark area.
Dimension
A
B
C
D
E
Pressure test
The Rapid injector is used as a pressure test
point.
1. Connect the pressure gauge to the Rapid
injector.
2. Examine the supply pressure by turning the
Rapid burner and one other burner fully on,
and lighting them. The pressure must be:
a) 20 mbar for Natural Gas
b) 29 mbar for LPG, butane only
c) 37 mbar for LPG, propane only.
3. Turn the taps off and disconnect the pres-
sure gauge.
www.zanussi.com
4. Make sure that all burners work correctly.
Checking the grill
1. Put in the grill pan containing the grid.
2. Light the grill burner by turning the grill con-
3. Release the knob when the burner comes
Checking the hob burners
E
1. Lift the lid.
2. Put in the burner crowns and caps. Make
D
3. Put in the pan supports.
4. Check each of the burners in turn by turning
C
5. Release the knob when the burners come
Checking the oven burners
1. Push the gas oven control knob and turn it
2. Keep it pushed until the oven burners come
mm
250
3. Set the flame.
680
4. Turn the control knob off and check that the
50
250
Electrical installation
580
the chapter "Safety information".
This appliance is supplied with a main plug and
a main cable.
time.
MANUFACTURER:
ELECTROLUX POLAND Sp.z o.o..
ul.Kazimierza Odnowiciela 28
58-100 Świdnica - POLAND
trol knob to the symbol
on.
sure that they are correctly seated.
the burner control knob to the symbol
on.
to
position.
on (about 10 seconds).
oven flames go out.
The manufacturer is not responsible if you
do not follow the safety precautions from
Connect the phases correctly, if you do not
connect, spark generator will work all the
.
.
21