DP2 AC Power Ratings
Description
Idle (Sleep Mode)
Quiescent Power Draw
1/8th Power, Pink Noise (UL/CSA)
1/3rd Power, Pink Noise
Maximum Power Draw
Inrush Current
AC Power Module Connectors
Inlet Connector Rating
Outlet Connector Rating
DP1 AC Power Ratings
Description
Idle (Sleep Mode)
Quiescent Power Draw
1/8th Power, Pink Noise (UL/CSA)
1/3rd Power, Pink Noise
Maximum Power Draw
Inrush Current
AC Power Module Connectors
Inlet Connector Rating
Outlet Connector Rating
Line Voltage Selection: The DrivePack
automatically select the correct operating voltage range window. Automatic voltage selection is between
100-120VAC and 200-240VAC operation, 50/60Hz.
Line Voltage Tolerance: The amp will operate normally (with expected de-rating in power output during low
line conditions) over a range of 100-120VAC +/-10% or 200-240VAC +/-10% AC input voltage. The amp will
shut down for voltages below nominal line and self protect for over-voltage beyond 15% nominal line.
CAUTION: Continuous voltages 10% beyond high line at either 120VAC or 240VAC operation
ranges can disrupt performance of the JBL DRIVEPACK! To avoid activation of amplifier low line/
high line protection which will interrupt audio performance, the system operator should maintain
AC supply voltages within the rated voltage windows.
120VAC
20W
75W
400W, 4A rms
8 A
3950W
Inrush current limiting via PTC soft-start
12A Max, 100-120VAC/220-240VAC, 50-60 Hz.
Class 1 Wiring
4A
8A
120VAC
10W
60W
600W, 5A rms
9 A
4500W
Inrush current limiting via PTC soft-start
12A Max, 100-120VAC/220-240VAC, 50-60 Hz.
Class 1 Wiring
5A
7A
features an international Auto-Sensing power supply and will
®
240VAC
400W, 3A rms
4.6 A
16 AWG
(1.5 mm
3A
9A
240VAC
600W, 3.2A rms
6 A
16 AWG
(1.5 mm
3.2A
8.8A