RBI LCD Series Installation & Operation Manual page 27

Lcd series finned copper gas boilers & water heaters
Hide thumbs Also See for LCD Series:
Table of Contents

Advertisement

DANGER: Propane gas may not always be
detected by smell. Propane gas is heavier than
air and can collect in low areas.
Propane gas can ignite or explode if an ignition
source is present and result in death, serious
injury and property damage!
FOR YOUR SAFETY
•Have only qualified licensed professionals install,
service and maintain this appliance and your gas
system in accordance with all applicable codes.
•Install a nationally listed combustible gas
detector(s) in your home.
•If you suspect a leak:
1. Have everyone leave the building immediately.
2. Do not attempt to light any appliance.
3. Do not touch any electrical or electronic switches
in the building.
4. Do not use any phone in the building.
5. Call your gas supplier from a phone outside of
the building.
6. If you cannot reach your gas supplier call the fire
department.
AVANT DE FAIRE FONCTIONNER, reniflez tout autour
de l'appareil pour déceler une odeur de gaz. Reniflez
près du plancher, car certains gaz sont plus lourds que
l'air et peuvent s'accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur; ne pas vous servir
des téléphones se trouvant dans le bâtiment.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suives les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur, appelez
le service de incendies.
C. Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to replace
any part of the control system and any gas control
that has been under water.
N'utilisez pas cet appareil s'il a été plongé dans
l'eau, même par tiellement. Faites inspecter
l'appareil par un tecnicien qualifié et remplacez
toute partie du système de contrôle et toute
commande qui ont été plongés dans l'eau.
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above. If, at
any time, the appliance will not operate properly,
follow the instructions "TO TURN OFF GAS TO
APPLIANCE" and call your service technician or gas
supplier.
LCD INSTALLATION AND OPERATION INSTRUCTIONS
2. Set the operating control or thermostat to off or its
lowest setting.
3. Turn off all electric power to the appliance.
4. Close the main manual gas shut-off valve, Figure 16.
5. Wait five (5) minutes to clear out any gas.
6. Remove the upper front jacket panel.
7. Turn the knob on the pilot valve to off, Figure 18.
8. Turn the knob on the main gas valve to off, 225
through 400 models, Figure 18. On 600 through
2300 models close the manual shutoff valve located
in the control compartment, Figure 19.
9. Locate pilot and manifold pressure taps in the
upper compartment. Remove the 1/8" screw plugs,
see Figure 19.
Figure 18 - Pilot Valve (All Models)
Main Valve (225 - 400 Models)
10. Connect a 20 in, 508 mm W.C . manometer to each
valve, see Figure 19.
11. Turn the knob on the pilot valve to on, Figure 18.
12. Turn the knob on the main gas valve to on, 225
through 400 models, Figure 18. On 600 through
2300 models open the manual shutoff valve located
in the control compartment, Figure 19.
13. Make sure that the gas supply piping has been
purged of air and that all gas joints up to the gas
valve have been thoroughly checked for leaks.
14. Turn on all electric power to the boiler.