Dell PowerEdge R520 Owner's Manual

Dell PowerEdge R520 Owner's Manual

Hide thumbs Also See for PowerEdge R520:
Table of Contents

Advertisement

Dell PowerEdge R520
Owner's Manual
Regulatory Model: E19S Series
Regulatory Type: E19S001

Advertisement

Table of Contents
loading

Summary of Contents for Dell PowerEdge R520

  • Page 1 Dell PowerEdge R520 Owner's Manual Regulatory Model: E19S Series Regulatory Type: E19S001...
  • Page 2 CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2013 Dell Inc. All Rights Reserved. Trademarks used in this text: Dell , the Dell logo, Dell Boomi...
  • Page 3: Table Of Contents

    Contents 1 About Your System........................9 ........................9 Front-Panel Features And Indicators ..............................11 LCD Panel Features ..............................11 Home Screen ..............................12 Setup Menu ............................... 12 View Menu ..........................13 Hard-Drive Indicator Patterns ........................14 Back-Panel Features And Indicators ..............................15 NIC Indicator Codes ............................
  • Page 4 ............................31 Boot Manager Screen ............................... 32 UEFI Boot Menu ..........................32 Embedded System Management ..............................32 iDRAC Settings Utility ........................32 Entering The iDRAC Settings Utility ........................32 Changing The Thermal Settings 3 Installing System Components....................35 .............................. 35 Recommended Tools ............................. 35 Front Bezel (Optional) ..........................35 Installing The Front Bezel ..........................36...
  • Page 5 ..........................57 Installing The Optical Drive ................................57 Cooling Fans ...........................57 Removing A Cooling Fan ............................58 Installing A Cooling Fan ........................59 Internal USB Memory Key (Optional) ........................59 Replacing the Internal USB Key ......................60 Expansion Cards And Expansion-Card Risers ......................60 Expansion-Card Installation Guidelines ..........................
  • Page 6 Troubleshooting A Hard Drive ........................108 Troubleshooting A Storage Controller ........................109 Troubleshooting Expansion Cards ..........................110 Troubleshooting Processors 5 Using System Diagnostics..................... 111 ............................111 Dell Online Diagnostics ........................111 Dell Embedded System Diagnostics ..................111 When To Use The Embedded System Diagnostics...
  • Page 7 7 Technical Specifications....................... 117 8 System Messages........................123 ..............................123 LCD Messages ..........................123 Viewing LCD Messages ..........................123 Removing LCD Messages ............................123 System Error Messages ...............................139 Warning Messages ............................139 Diagnostic Messages ..............................139 Alert Messages 9 Getting Help..........................141 ..............................141 Contacting Dell...
  • Page 9: About Your System

    About Your System Front-Panel Features And Indicators Figure 1. Front-Panel Features and Indicators Figure 2. Front-Panel Features and Indicators for a Software RAID System Item Indicator, Button, or Icon Description Connector Power-on indicator, power The power-on indicator lights when the system power is button on.
  • Page 10 Item Indicator, Button, or Icon Description Connector Use this button only if directed to do so by qualified support personnel or by the operating system's documentation. System identification button The identification buttons on the front and back panels can be used to locate a particular system within a rack. When one of these buttons is pushed, the LCD panel on the front and the system status indicator on the back flashes blue until one of the buttons is pushed again.
  • Page 11: Lcd Panel Features

    LCD Panel Features The system's LCD panel provides system information and status and error messages to indicate when the system is operating correctly or when the system needs attention. See LCD Error Messages for information about specific error codes. • The LCD backlight lights blue during normal operating conditions and lights amber to indicate an error condition.
  • Page 12: Setup Menu

    Setup Menu NOTE: When you select an option in the Setup menu, you must confirm the option before proceeding to the next action. Option Description iDRAC Select DHCP or Static IP to configure the network mode. If Static IP is selected, the available fields are IP, Subnet (Sub), and Gateway (Gtw).
  • Page 13: Hard-Drive Indicator Patterns

    Hard-Drive Indicator Patterns Figure 4. Hard-Drive Indicators hard-drive activity indicator (green) hard-drive status indicator (green and amber) NOTE: If the hard drive is in Advanced Host Controller Interface (AHCI) mode, the status indicator (on the right side) does not function and remains off. Drive-Status Condition Indicator Pattern...
  • Page 14: Back-Panel Features And Indicators

    Back-Panel Features And Indicators Figure 5. Back-Panel Features and Indicators—Redundant Power Supply Unit Chassis Figure 6. Back-Panel Features and Indicators—Non-Redundant Power Supply Unit Chassis Item Indicator, Button, or Icon Description Connector PCIe expansion card slot 1 Connects a PCI Express expansion card. vFlash media card slot Allows you to insert a vFlash media card.
  • Page 15: Nic Indicator Codes

    Item Indicator, Button, or Icon Description Connector the front and the system status indicator on the back blink until one of the buttons is pushed again. Press to toggle the system ID on and off. If the system hangs during POST, press and hold the system ID button for more than five seconds to enter BIOS progress mode.
  • Page 16 Figure 8. AC Power Supply Status Indicator AC power supply status indicator/handle Figure 9. DC Power Supply Status Indicator DC power supply status indicator Power Indicator Condition Pattern Not lit Power is not connected. Green The handle/LED indicator lights green indicating that a valid power source is connected to the power supply and that the power supply is operational.
  • Page 17: Power Indicator Codes For Non-Redundant Power Supply

    Power Indicator Condition Pattern CAUTION: AC power supplies support both 220 V and 110 V input voltages with the exception of Titanium power supplies, which support only 220 V. When two identical power supplies receive different input voltages, they can output different wattages, and trigger a mismatch.
  • Page 18: Other Information You May Need

    • For the full name of an abbreviation or acronym used in this document, see the Glossary at www.dell.com/support/ manuals. NOTE: Always check for updates on www.dell.com/support/manuals and read the updates first because they often...
  • Page 19: Using The System Setup And Boot Manager

    The exact LC2 feature set is determined by the iDRAC license purchased. For more information, see the Dell LC2 documentation. Enters the BIOS Boot Manager or the Unified Extensible <F11>...
  • Page 20: Entering System Setup

    NOTE: Operating systems must be UEFI-compatible to be installed from the UEFI boot mode. DOS and 32-bit operating systems do not support UEFI and can only be installed from the BIOS boot mode. NOTE: For the latest information on supported operating systems, go to dell.com/ossupport. Entering System Setup Turn on or restart your system.
  • Page 21: System Setup Options

    System Setup Options System Setup Main Screen NOTE: Press <Alt><F> to reset the BIOS or UEFI settings to their default settings. Menu Item Description System BIOS This option is used to view and configure BIOS settings. iDRAC Settings This option is used to view and configure iDRAC settings. Device Settings This option is used to view and configure device settings.
  • Page 22: Memory Settings Screen

    Mode configuration of your system are Optimizer Mode, Advanced ECC Mode, Mirror Mode, Spare Mode, Spare with Advanced ECC Mode, and Dell Fault Resilient Mode. By default, the Memory Operating Mode option is set to Optimizer Mode. NOTE: The Memory Operating Mode can have different defaults and available options based on the memory configuration.
  • Page 23 Menu Item Description NOTE: The QPI speed option displays only when both the processors are installed. Alternate RTID Allows you to allocate more RTIDs to the remote socket increasing cache performance (Requestor between the sockets or work in normal mode for NUMA. By default, the Alternate RTID Transaction ID) (Requestor Transaction ID) Setting is set to Disabled.
  • Page 24: Sata Settings Screen

    SATA Settings Screen Menu Item Description Embedded SATA Allows the embedded SATA to be set to Off, ATA, AHCI, or RAID modes. By default, the Embedded SATA option is set to AHCI. Port E Auto enables BIOS support for the device attached to SATA port E. Off disables BIOS support for the device.
  • Page 25: Serial Communications Screen

    Menu Item Description Internal SD Card Port Enables or disables the system’s internal SD card port. By default, Internal SD Card Port option is set to On. NOTE: This option is displayed only if IDSDM is installed on the system board. Internal SD Card If set to Mirror mode, data is written on both SD cards.
  • Page 26: System Profile Settings Screen

    Custom. By default, the System Profile option is set to Performance Per Watt Optimized (DAPC). DAPC is Dell Active Power Controller. NOTE: The following parameters are available only when the System Profile is set to Custom.
  • Page 27: System Security Screen

    BIOS updates, it is recommended to set this field to Disabled. By default, the BIOS Update Control option is set to Unlocked. NOTE: BIOS updates using Dell Update Package are not affected by this option. Power Button Allows you to enable or disable the power button on the front of the system.
  • Page 28: Miscellaneous Settings

    Menu Item Description AC Power Recovery Allows you to set how the system reacts after AC power is restored to the system. By default, the AC Power Recovery option is set to Last. AC Power Recovery Allows you to set how the system supports staggering of power up after AC power is restored Delay to the system.
  • Page 29: Assigning A System And/Or Setup Password

    Assigning A System And/Or Setup Password NOTE: The password jumper enables or disables the System Password and Setup Password features. For more information on the password jumper settings, see System Board Jumper Settings. You can assign a new System Password and/or Setup Password or change an existing System Password and/or Setup Password only when the password jumper setting is enabled and Password Status is Unlocked.
  • Page 30: Using Your System Password To Secure Your System

    In the System Security screen, verify that Password Status is Unlocked. Select System Password, alter or delete the existing system password and press <Enter> or <Tab>. Select Setup Password, alter or delete the existing setup password and press <Enter> or <Tab>. NOTE: If you change the System and/or Setup password a message prompts you to re-enter the new password.
  • Page 31: Using The Boot Manager Navigation Keys

    Displays a list of the drivers installed on the system and their health status. Launch System Setup Enables you to access the System Setup. System Utilities Enables you to access the BIOS Update File Explorer, run the Dell Diagnostics program, and reboot the system.
  • Page 32: Uefi Boot Menu

    Sets a one-time boot option not included in the boot option list. Embedded System Management The Dell Lifecycle Controller provides advanced embedded systems management throughout the server’s lifecycle. The Lifecycle Controller can be started during the boot sequence and can function independently of the operating system.
  • Page 33 NOTE: When the User Option is set to the default Auto setting, the user option cannot be modified. Set the Maximum Air Exhaust Temperature or the Fan Speed Offset fields. Click Back → Finish → Yes.
  • Page 35: Installing System Components

    Installing System Components Recommended Tools You may need the following items to perform the procedures in this section: • Key to the system keylock • #1 and #2 Phillips screwdrivers • T10 and T15 Torx screwdrivers • Wrist grounding strap connected to ground Following tools are required for assembling cables for a DC power supply unit (PSU), when available: •...
  • Page 36: Removing The Front Bezel

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 37: Closing The System

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 38 Figure 13. Inside the System—Redundant Power Supply Unit Chassis cooling shroud cooling fans (6) expansion-card latch optical drive (optional) power supply (redundant) hard drives (8) expansion-card riser 2 information tag expansion card control-panel board expansion-card latch hard-drive backplane expansion-card riser 1 power-distribution board heat sink for processor 1 power-interposer board...
  • Page 39: Cooling Shroud

    Figure 14. Inside the System—Non-Redundant Power Supply Unit Chassis cooling shroud DIMMs (12) expansion-card latch cooling fans (6) power supply (non-redundant) optical drive (optional) expansion-card riser 2 hard drives (8) expansion card information tag expansion-card latch control-panel board expansion-card riser 1 hard-drive backplane heat sink for processor 1 Cooling Shroud...
  • Page 40: Removing The Cooling Shroud

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 41: Installing The Cooling Shroud

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 42 NOTE: DIMMs in sockets A1 to A6 are assigned to processor 1 and DIMMs in sockets B1 to B6 are assigned to processor 2. Figure 16. Memory Socket Locations Memory channels are organized as follows: Processor 1 channel 1: memory sockets A1 and A4 channel 2: memory sockets A2 and A5 channel 3: memory sockets A3 and A6 Processor 2...
  • Page 43: General Memory Module Guidelines

    General Memory Module Guidelines This system supports Flexible Memory Configuration, enabling the system to be configured and run in any valid chipset architectural configuration. The following are the recommended guidelines for best performance: • UDIMMs and RDIMMs must not be mixed. •...
  • Page 44: Memory Optimized (Independent Channel) Mode

    NOTE: Advanced ECC with mirroring is not supported. Memory Optimized (Independent Channel) Mode This mode supports SDDC only for memory modules that use x4 device width and does not impose any specific slot population requirements. Memory Sparing NOTE: To use memory sparing, this feature must be enabled in the System Setup. In this mode, one rank per channel is reserved as a spare.
  • Page 45 System Capacity DIMM Size (in Number of Organization and DIMM Slot Population (in GB) DIMMs Speed 1R x8, 1600 MT/s 1R x8, 1333 MT/s A1, A2, A3, A4, A5 1R x8, 1600 MT/s 1R x8, 1333 MT/s A1, A2, A3 1R x8, 1600 MT/s 1R x8, 1333 MT/s A1, A2, A3, A4, A5...
  • Page 46: Removing Memory Modules

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 47: Installing Memory Modules

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 48: Hard Drives

    CAUTION: To prevent damage to the memory-module socket during installation, apply pressure at both ends of the memory module evenly. Do not apply pressure to the center of the memory module. Press down on the memory module with your thumbs until the memory module snaps into place. Figure 19.
  • Page 49: Removing A 3.5 Inch Hard-Drive Blank

    CAUTION: Before attempting to remove or install a hard drive while the system is running, see the documentation for the storage controller card to ensure that the host adapter is configured correctly to support hot-swap hard drive removal and insertion. CAUTION: Do not turn off or reboot your system while the hard drive is being formatted.
  • Page 50: Removing A Dual Slot Hard-Drive Blank

    Figure 21. Hard-Drive Blank Installation Sequence Removing A Dual Slot Hard-Drive Blank CAUTION: To maintain proper system cooling, all empty hard-drive slots must have hard-drive blanks installed. NOTE: Systems configured for software RAID support only four hard drives. The remaining hard-drive slots are pre- installed with dual slot hard-drive blanks, and are not available for software RAID.
  • Page 51: Installing A Dual Slot Hard-Drive Blank

    Figure 22. Removing and Installing A Dual Slot Hard-Drive Blank dual slot hard-drive blank release tabs (2) Installing A Dual Slot Hard-Drive Blank If installed, remove the front bezel. Insert the dual slot hard-drive blank into the hard-drive slot, and push it until the release tabs click into place. If applicable, install the front bezel.
  • Page 52: Installing A Hot-Swap Hard Drive

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 53: Removing A 2.5 Inch Hard Drive From A 3.5 Inch Hard-Drive Adapter

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 54 Figure 25. Removing and Installing a Hot-Swap Hard Drive Into a Hard-Drive Carrier hard-drive carrier screws (4) hard drive screw holes (4)
  • Page 55: Installing A Hard Drive Or A Hard-Drive Adapter Into A Hard-Drive Carrier

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 56: Optical Drive (Optional)

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 57: Installing The Optical Drive

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 58: Installing A Cooling Fan

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 59: Internal Usb Memory Key (Optional)

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 60: Expansion Cards And Expansion-Card Risers

    Figure 29. Replacing the Internal USB Key USB memory key connector USB memory key Expansion Cards And Expansion-Card Risers NOTE: A missing or an unsupported expansion-card riser logs an SEL event. It does not prevent your system from powering on and no BIOS POST message or F1/F2 pause is displayed. Expansion-Card Installation Guidelines Your system supports: •...
  • Page 61: Removing An Expansion Card

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 62 Figure 30. Removing and Installing the Expansion Card from Expansion-Card Riser 1 expansion card expansion-card latch riser 1...
  • Page 63: Installing An Expansion Card

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 64: Removing Expansion-Card Risers

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 65: Installing Expansion-Card Risers

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 66: Removing The Idrac Ports Card

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 67: Installing The Idrac Ports Card

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 68: Sd Vflash Card

    A vFlash SD card is a Secure Digital (SD) card that plugs into the vFlash SD card slot in the system. It provides persistent on-demand local storage and a custom deployment environment that allows automation of server configuration, scripts, iDRAC7 User's Guide at dell.com/support/ and imaging. It emulates USB device(s). For more information, see the manuals.
  • Page 69: Removing The Internal Dual Sd Module

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 70: Installing The Internal Dual Sd Module

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 71: Integrated Storage Controller Card

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 72: Installing The Integrated Storage Controller

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 73: Processors

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 74 Figure 38. Removing and Installing the Heat Sink retention sockets (4) heat sink retention screws (4) CAUTION: The processor is held in its socket under strong pressure. Be aware that the release lever can spring up suddenly if not firmly grasped. Position your thumb firmly over the processor socket-release lever and release the lever from the locked position.
  • Page 75: Installing A Processor

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 76: Power Supplies

    NOTE: You can update the system BIOS using the Lifecycle Controller. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. When disconnected from power, press and hold the power button for three seconds to fully drain the system of stored power prior to removing the cover.
  • Page 77: Removing An Ac Power Supply

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 78: Installing An Ac Power Supply

    DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.
  • Page 79 DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.
  • Page 80 DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.
  • Page 81: Removing A Dc Power Supply

    DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.
  • Page 82: Removing The Power Supply Blank

    NOTE: The maximum output power (shown in Watts) is listed on the power supply label. If applicable, remove the power supply blank. Slide the new power supply into the chassis until the power supply is fully seated and the release latch snaps into place.
  • Page 83: Removing The Power-Distribution And Power-Interposer Boards

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 84 screws (4) power-distribution board connector power-interposer board release tab Figure 46. Power-Distribution Board Connectors fan 6 cable connector power-distribution board connector 8-pin power connector...
  • Page 85: Installing The Power-Distribution And Power-Interposer Boards

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 86: Removing A Non-Redundant Power Supply

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 87 Figure 48. Removing and Installing a Non-Redundant Power Supply chassis screw power cable (24 pins) power supply unit cage power cable (8 pins) power supply hard-drive backplane power cable standoff on the chassis...
  • Page 88: Installing A Non-Redundant Power Supply

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 89: Installing The Redundant Power Supply Unit Divider

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 90: System Battery

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 91: Hard-Drive Backplane

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 92 Figure 51. Removing and Installing the Hard-Drive Backplane securing hooks backplane power connector securing slot SAS B connector release tabs (2) hard-drive backplane SAS A connector hard-drive connectors (8) backplane signal connector...
  • Page 93 Figure 52. Cabling Diagram of the Hard-Drive Backplane for a Redundant PSU System system board SAS A cable connector hard-drive backplane cable routing guide SAS B cable connector power distribution board power cable connector cable retention latch signal cable connector...
  • Page 94: Installing The Hard-Drive Backplane

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 95: Control Panel Assembly

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 96: Installing The Control-Panel Board

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 97: Installing The Control Panel

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 98: Removing The System Board

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 99: Installing The System Board

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 100 If applicable, install the front bezel. 10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. iDRAC7 User's Guide , at dell.com/ 11. Import your new or existing iDRAC Ports license. For more information, see...
  • Page 101: Troubleshooting Your System

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 102: Troubleshooting A Serial I/O Device

    Power down all attached USB devices and disconnect them from the system. Restart the system and, if your keyboard is functioning, enter the System Setup. Verify that all USB ports are enabled on the Integrated Devices screen, in the System Setup options. If your keyboard is not functioning, you can also use remote access.
  • Page 103: Troubleshooting A Wet System

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 104: Troubleshooting The System Battery

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 105: Troubleshooting Cooling Problems

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 106: Troubleshooting An Internal Usb Key

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 107: Troubleshooting An Optical Drive

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 108: Troubleshooting A Hard Drive

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 109: Troubleshooting Expansion Cards

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 110: Troubleshooting Processors

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 111: Using System Diagnostics

    Dell Online Diagnostics Dell Online Diagnostics, a stand-alone suite of diagnostic programs or test modules, allows you to run diagnostic tests on the systems in a production environment, and helps you ensure maximum uptime of your systems. Online Diagnostics allows you to run diagnostic tests on chassis and storage components such as hard drives, physical memory, and network interface cards (NICs).
  • Page 112: System Diagnostic Controls

    Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one event description is recorded. Dell Enhanced Pre-boot System Assessment User Guide at For information about embedded system diagnostics, see the...
  • Page 113: Jumpers And Connectors

    Jumpers And Connectors System Board Jumper Settings For information on resetting the password jumper to disable a password, see Disabling A Forgotten Password. Table 5. System Board Jumper Settings Jumper Setting Description PWRD_EN The password feature is enabled (pins 2–4). (default) The password feature is disabled (pins 4–6).
  • Page 114: System Board Connectors

    System Board Connectors Figure 56. System Board Connectors and Jumpers Item Connector Description INT_STORAGE Storage controller card connector ID_BTN System identification button CMA_JACK System identification connector USB 2 USB connector USB 1 USB connector IO_RISER2 Riser 2 connector NIC2 Network connector NIC1 Network connector Video connector...
  • Page 115: Disabling A Forgotten Password

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 116 Open the system. Move the jumper on the system-board jumper from pins 2 and 4 to pins 4 and 6. Close the system. 10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. 11.
  • Page 117: Technical Specifications

    Technical Specifications Processor Processor type One or two Intel Xeon processor E5-2400 and E5-2400 v2 product family Expansion Bus Bus type PCI Express Generation 2 and Generation 3 Expansion slots using riser card for a one processor system: Riser 1 (Slot 1) One half-height, half-length x4 link with x8 slot Riser 2 (Slot 2) One full-height, full-length x8 link with x16 slot...
  • Page 118 Memory Minimum RAM 2 GB (single processor configuration) Maximum RAM 384 GB Drives Up to eight 3.5 inch or 2.5 inch, internal, hot-swappable Hard drives SAS, SATA, SAS SSD. SATA SSD, or Nearline SAS hard drives in hard-drive slots 0 through 7. Up to four 3.5 inch or 2.5 inch, internal, hot-swappable SAS, SATA, SAS SSD, SATA SSD, or Nearline SAS hard drives in hard-drive slots 0 through 3 for a software RAID...
  • Page 119 Allow processor performance degrade. • Non-redundant power supplies are not supported. • Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported. • Maximum altitude for the operating temperature must be 3050 m (10,000 ft).
  • Page 120 Environmental Temperature Ranges (for altitude less than 950 m or 3117 10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on the equipment. Humidity Percentage Range 10% to 80% Relative Humidity with 26 °C (78.8 °F) maximum dew point.
  • Page 121 Environmental Conductive Dust Air must be free of conductive dust, zinc whiskers, or other conductive particles. NOTE: Applies to data center and non-data center environments. Corrosive Dust • Air must be free of corrosive dust. • Residual dust present in the air must have a NOTE: Applies to data center and non-data center deliquescent point less than 60% relative humidity.
  • Page 123: System Messages

    System Messages LCD Messages NOTE: Applicable only if your system has an LCD display. The LCD messages consist of brief text messages that refer to events recorded in the System Event Log (SEL). For information on the SEL and configuring system management settings, see the systems management software documentation.
  • Page 124 Error Code Message Information AMP0302 name > current is greater than the upper warning Message The system board < threshold. name > current is outside of the optimum range. Details System board < Action Review system power policy. Check system logs for power related failures. Review system configuration changes.
  • Page 125 Error Code Message Information ASR0003 Message The watchdog timer power cycled the system. Details The operating system or an application failed to communicate within the time-out period. The system was power-cycled. Action Check the operating system, application, hardware, and system event log for exception events.
  • Page 126 Error Code Message Information Action Review the technical specifications for supported processor types. CPU0010 number > is throttled. Message CPU < Details The CPU is throttled due to thermal or power conditions. Action Review system logs for power or thermal exceptions. CPU0023 number >...
  • Page 127 Error Code Message Information Turn off the system and remove input power for one minute. Ensure the processor is seated correctly. Reapply input power and turn on the system. If the issue persists, see Getting Help. CPU0702 Message CPU bus parity error detected. LCD Message CPU bus parity error detected.
  • Page 128 Error Code Message Information If the issue persists, see Getting Help. FAN0000 number > RPM is less than the lower warning threshold. Message Fan < Details Fan operating speed is out of range. Action Remove and reinstall the fan. If the issue persists, see Getting Help.
  • Page 129 Error Code Message Information Action Check if the cable is present, then reinstall or reconnect. MEM0000 Message Persistent correctable memory errors detected on a memory device location >. at location(s) < Details This is an early indicator of a possible future uncorrectable error. Action Re-seat the memory modules.
  • Page 130 Error Code Message Information location >. Power cycle system. LCD Message Memory mirror lost on < Details The memory may not be seated correctly, misconfigured, or has failed. Action Check the memory configuration. Re-seat the memory modules. If the issue persists, see Getting Help.
  • Page 131 Error Code Message Information Action Cycle input power, update component drivers, if device is removable, reinstall the device. PCI1320 Message A bus fatal error was detected on a component at bus bus >device< device >function < func >. < bus > device < device > function < func >. Power LCD Message Bus fatal error on bus <...
  • Page 132 Error Code Message Information number > removed from disk drive bay < bay >. Check drive. LCD Message Drive < Details The controller detected that the drive was removed. Action Verify drive installation. Re-seat the failed drive. If the issue persists, Getting Help.
  • Page 133 Error Code Message Information PSU0006 number > type mismatch. Message Power supply < LCD Message Power supply < number > is incorrectly configured. Check PSU. Details Power supplies should be of the same input type and power rating. Action Install matched power supplies and review proper configuration in this manual.
  • Page 134 Error Code Message Information PSU0034 number >. Message An under voltage fault detected on power supply < LCD Message An under voltage fault detected on PSU < number >. Check power source. Details This failure may be the result of an electrical issue with cables or subsystem components in the system.
  • Page 135 Error Code Message Information PSU1201 Message Power supply redundancy is lost. Details The power supply tries to operate in a degraded state. System Performance and power redundancy may be degraded or lost. Action Check input power. Reinstall the power supply. If the issue persists, Getting Help.
  • Page 136 Error Code Message Information Details An error was reported during a SD card read or write. Action Reseat the flash media. If the problem persists, see Getting Help. RFM1014 name > is write protected. Message Removable Flash Media < name > is write protected. Check SD Card. LCD Message Removable Flash Media <...
  • Page 137 Error Code Message Information SEC0031 Message The chassis is open while the power is on. LCD Message Intrusion detected. Check chassis cover. Details The chassis is open. System performance may be degraded, and security may be compromised. Action Close the chassis. Check system logs. SEC0033 Message The chassis is open while the power is off.
  • Page 138 Error Code Message Information Action Re-configure system to the minimum supported configuration. If issues persists, contact support. TMP0118 Message The system inlet temperature is less than the lower warning threshold. LCD Message System inlet temperature is outside of range. Details Ambient air temperature is too cool.
  • Page 139: Warning Messages

    Error Code Message Information Action Review system logs for power supply exceptions. Re-configure the system to minimum configuration, inspect and reinstall system cables. If the issue persists, see Getting Help. Warning Messages A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a hard drive, a message warns you that you may lose all data on the hard drive.
  • Page 141: Getting Help

    Dell product catalog. Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues: Visit dell.com/support...

This manual is also suitable for:

E19s001

Table of Contents