Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if the
fireplace is to be vented out the top.
NOTE: Unit requires 12 inches of rise before elbow, as well
as 2 inches of clearance around first 12 inches of pipe.
Figure 25
The following vent systems are acceptable for use:
Simpson Duravent® GS 4" - 6 ⅝"
American Metal Products 4" - 6-5/8"
Selkirk Direct-Temp® 4" - 6-5/8"
Security Secure Vent® 4" - 6-5/8"
Empire Flexvent Kit DVVK-4F, refer to page 36 - 37.
Page 16

VENT SYSTEM IDENTIFICATION

Special Venting Components (Simpson Duravent)
See Empire Comfort Systems Retail Price List for Simpson Duravent part numbers
and pricing.
DVVK-4FV
DVVK-4VP
DVVK-4TP
DVVK-4TSP

SPECIAL VENT SYSTEMS

Special DV Vent Kits
Available from Empire Comfort Systems, Inc. dealers
Vertical Flex Vent Kit 4" x 7"
Direct-Vent Fireplace Vent Kit - Vertical.
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 8 to
11 inch wall thickness, Includes SD-911, SD-985, SD-990 and
SD-942
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 5 to
7 inch wall thickness, Includes SD-908, SD-985, SD-990 and
SD-942