Verifying the Installation

Figure 7
FAN
STATUS
e.
This completes the CSM installation procedure.
Verifying the Installation
When you install the CSM in a Catalyst 6500 series switch, the module goes through a startup sequence
that requires no intervention. At the successful conclusion of the startup sequence, the green Status LED
will light and remain on. If the Status LED does not show green, or if it shows a different color, refer to
Table 1 on page 8

Using the CLI

The software interface for the module is the Cisco IOS and the Catalyst operating system command-line
interface accessed through a Telnet connection to the switch or through the switch console interface.
Refer to the Catalyst 6500 Series Switch Cisco IOS Software Configuration Guide and the Catalyst 6500
Series Switch Software Configuration Guide for details.
Catalyst 6500 Series Switch Content Switching Module Installation Note
20
Ejector Lever Closure in a Vertical Slot Chassis
All ejector levers flush
with module faceplate
Tighten the two captive installation screws on the module.
Note
Make sure that the ejector levers are fully closed before tightening the captive installation
screws.