Scan And Sync; Multiple System Setup; Non-Networked Receivers - Shure ULX-D Manual

Digital wireless microphone system
Hide thumbs Also See for ULX-D:
Table of Contents

Advertisement

Scan and Sync

Use this procedure to tune a receiver and transmitter to the best open channel.
Important! Before you begin:
Turn off all transmitters for the systems you are setting up. (This prevents
them from interfering with the frequency scan.)
Turn on potential sources of interference such as other wireless systems or
devices, computers, CD players, large LED panels, effects processors, and
digital rack equipment so they are operating as they would be during the
presentation or performance (so the scan will detect and avoid any interfer-
ence they generate).
1. Perform a channel scan on the receiver:
2. Select a group and press the
LCD while it searches for an open frequency.
3. After the scan completes, the receiver displays the group, channel and
frequency of the best available channel. Press the flashing
to save the value to the receiver.
4. Power on the ULXD transmitter.
5. Press the
button on the receiver.
sync
6. Align the IR windows until the receiver IR port illuminates red.
7. When complete,
SYNC SUCCESS!
are now tuned to the same frequency.

Multiple System Setup

A setup using networked receivers is the fastest and easiest way to distrib-
ute the best open channel to each system. See Networking Receivers for
networking details.
Networked Receivers
1. Turn on all receivers.
2. Conduct a group scan on the first receiver to find the best group of fre-
quencies in your RF environment:
3. Press
to accept the group number and automatically assign the
ENTER
next best channel to each receiver on the network.
4. Turn on a transmitter and sync to the receiver. Repeat this step for
each additional system.
8
>
SCAN
CHANNEL SCAN
button.
displays on the
SCAN
SCANNING
ENTER
appears. The transmitter and receiver
>
.
SCAN
GROUP SCAN
ULXD4
Digital Wireless Receiver
1
.
button
3
SCAN COMPLETE
G:01 CH:21
485.775 MHz
Rssi: -118 dBm
5
sync

Non-networked Receivers

1. Turn on all receivers.
2. Conduct a group scan on the first receiver to find the best group of fre-
quencies in your RF environment:
3. Select a group that contains enough open frequencies to accommodate
the entire setup.
4. Turn on the transmitter and sync to the first receiver.
Repeat the following steps for each additional system:
5. Go to
>
SCAN
signed in step 2
6. Press the
SCAN
7. Press
ENTER
8. Sync the transmitter to the receiver.
EXIT
control
RF
audio
AB
OL
ENTER
OL
SCAN
EXIT
sync
SCAN
push
2
EXIT
SCAN
4
ULXD2
6
>
SCAN
GROUP SCAN
on the receiver to select the group as-
CHANNEL SCAN
button to find the next best open frequency.
to assign the channel to the receiver.
gain
power
EXIT
SCAN
on

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents