3-7. PROGRAMMING
(Continued)
Displayed Step
23
24
30
3-14
Frigiprobe temperature for when the buzzer sounds at
the start of a cycle. Press
ture that the buzzer sounds when the product has reached the
"danger zone" temperature, and must be cooled to a "safe"
temperature within the recommended time, is shown in the
display.
The factory setting is 140ºF (60ºC), but can be changed to a
maximum setting of 176ºF (80ºC) and a minimum setting of
122ºF (50ºC) by using
The settings for the U.S.A. must be 140ºF (60ºC) and for
England, 158ºF (70ºC).
Intermediate Printer Setting. Press
printing temperature, between the starting temperature and the
ending temperature, can be set. Along with printing the tem-
perature information at the end of a cycle, the printer can be set
to capture temperature information in the middle of the cycle.
The factory setting is -40ºF (-40ºC), but can be changed to a
maximum setting of 176ºF (80ºC) and a minimum setting of
40ºF (-40ºC) by using
A setting lower than parameter
Selecting Fahrenheit or Celsius. Press
19 times and ºF or ºC shows in the display. Press
to change from ºF to ºC, or vice versa.
(Once
is pressed, the display goes blank.)
Model BCF-24/65/110, BCM-110
17 times, and the tempera-
.
18 times and a
.
deactivates this function.