CUSTOMER SUPPORT DO NOT RETURN THIS PRODUCT TO THE STORE WHERE YOU BOUGHT IT FOR IMMEDIATE CUSTOMER SERVICE, PLEASE CALL: 888-4BGT HEAT (888-424-8432) A CUSTOMER SERVICE REPRESENTATIVE WILL ASSIST YOU WITH ANY QUESTIONS REGARDING YOUR CONCEPT R-4 HEATER P a g e...
Page 3
Concept R4 is a 3-in-1 product, producing soft infrared heating, humidification, and year-round air purification all in one easy-to-use product. Please refer to our website for further information on all RedCore™ products. Best Green Technologies, LLC E-Mail: sales@bestgreenllc.com www.redcoreheaters.com 888-4BGT HEAT (888-424-8432)
Page 4
CAUTION! WARNING 1: WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PERSONS. WARNING 2: RISK OF ELECTRIC SHOCK. NO USER-SERVICABLE PARTS INSIDE EXCEPT TO CLEAN THE AIR FILTER AND HUMIDIFIER. WARNING 3: THIS PRODUCT MUST RUN ON ITS OWN ELECTRICAL CIRCUIT.
Page 5
12. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked. 13. The heater has hot parts and sparking parts inside. Do not use in areas where gasoline, paint, or flammable liquids are used or stored.
Page 6
Product specification and basic features Voltage 120V-60HZ Heating power: Up to1500 Watts. Temperature control range:60-90 degrees Fahrenheit Heating element: Infrared PTC heater Air purifier: lifetime washable air filter and PCO cell with separate control from heater operation ...
Main Features ON/OFF (I/O) switch located back of unit Humidifier water tank LCD Display Humidifier air outlet Hot air outlet Wireless receiver Overheat/Auto-Recovery indicator light Casters P a g e...
Page 8
LCD display and button instruction Power On/Off button: Turn on or turn off the heater Humidifier On/Off button: Turn on or turn off the humidifier function Room Setting button: Set the room size according to actual size of room and the heater will work at different power levels based on different room size settings: larger room = 1500 Watts;...
Remote Control unit How to Operate the Heater NOTE: The heater may emit a slight harmless smoke when first used. This smoke is a normal condition caused by initial heating of the infrared element. It will occur only briefly and is not harmful. ...
Page 10
Heater ON/OFF: Press the HEATER power button to turn on or off the heating function of the heater. The fan will stop operating until the heating element has reached a temperature high enough to begin the warming process. During the period that the fan does not operate, the message “HEATING UP” will show on the LCD display to indicate that the heating element is heating up.
Page 11
Delay Timer setting. Press this button to set the desired number of hours, and the unit will stop heating and will not start heating again until that amount of time has elapsed. For example, set the Delay Timer for 8 hours before you go to be at 10:00 pm, and the unit will turn on at 6:00 am.
Page 12
How to Refill the Humidifier Water Tank The Humidifier Water Tank is located on top of the unit. To fill the tank, simply remove the tank, unscrew the cap, and fill it with water (we recommend distilled water). Replace the cap and carefully place the tank back in the unit until it seats on the base of the Humidifier.
Page 13
4. To clean the base of the humidifier, moisten a soft cloth with warm water and a small amount of liquid soap. Gently wipe all residue from the base 5. If you are not going to use the humidifier for an extended period of time (for example during warm weather), drain all water out of the bottle and chamber and dry it out as much as possible using a soft towel.
Page 14
How to Clean the Air Purifier Filter Your Concept R4 heater comes with a PCO (Photo-Catalytic Oxidation) air purifier that combines high-intensity UV light with superior activated carbon honeycomb filter technology The lifetime washable air filter needs to be cleaned on a regular basis to ensure maximum performance of the air purifier and of the heater itself.
Caution!! Disconnect power cord before servicing Ensure that the heater is turned off (the switch on the back of the unit should be in the off position. Unplug the power cord from the wall outlet before cleaning. Carefully wipe the exterior of the heater with a soft, damp (not wet) cloth and dry thoroughly with a soft, dry cloth.
PERFORMANCE SUGGESTIONS To assure maximum performance of the heater, please note the following recommendations: 1) For best result, do not locate the heater in an area with a high rate of air filtration and movement as the warm air will be exhausted. 2) Try placing the heater near a warmer inside wall and direct the output towards a cooler outside wall.
QUESTIONS AND ANSWERS Why does the blower fan not work after I have turned on the heater power button? The blower fan will not work until the heating element is hot enough to heat the air passing by. It will normally turn on after about 10 seconds.
Page 18
few feet above the floor will allow for more efficient heating. Can I use more than one heater at a time? Yes, but you should make sure they are not on the same circuit. Each heater and appliance should be on its own circuit.
Page 19
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, salvaged, or refurbished products. To obtain warranty service, the defective product or part must be shipped or delivered to: Best Green Technologies, the Manufacturer. If warranty applies under BGT’s approved terms, all shipping charges and insurance are covered by purchaser.
Page 20
CUSTOMER SUPPORT DO NOT RETURN THIS PRODUCT TO THE STORE WHERE YOU BOUGHT IT FOR IMMEDIATE CUSTOMER SERVICE, PLEASE CALL: 888-4BGT HEAT (888-424-8432) A CUSTOMER SERVICE REPRESENTATIVE WILL ASSIST YOU WITH ANY QUESTIONS REGARDING YOUR CONCEPT R-4 HEATER 20 | P a g e...
Need help?
Do you have a question about the RedCore Concept R-4 and is the answer not in the manual?