Operation - Toyotomi TAD-T38J Instruction Manual

Hide thumbs Also See for TAD-T38J:
Table of Contents

Advertisement

Available languages

Available languages

3. OPERATION

BEFORE OPERATION:
INSTALLING FILTERS
CAUTION
¡ Be sure to install the filters before using the unit.
1. Pull the air intake grille (B1) ( J ) toward you and remove it.
2. Take the charcoal filter (B3) ( K ) out of the plastic bag.
3. Install the charcoal filter (B3) ( K ) by mounting the filter
clamp (B4) ( M ).
REMOTE CONTROL (Removable) (A1)
NOTE: This remote control can be stored on the top of the unit.
1. INSERTING BATTERIES
Remove the cover on the back of the remote
control and insert the batteries with the ( + ) and ( -
) poles pointing in the proper direction. (Fig. H)
CAUTION
¡ Use only AAA or IEC R03 1.5V batteries
¡ DO NOT attempt to recharge the supplied batteries.
¡ All batteries should be replaced at the same time.
¡ DO NOT dispose of the batteries in a fire as they may ex-
plode.
¡ DO NOT install the batteries with the polarity (+/-) re-
versed.
¡ Keep batteries and other things that could be swallowed
away from young children. Contact a doctor immediately
if an object is swallowed.
2. SET CLOCK
Press CLOCK button (C6), LCD clock display flashes. Press
UP button "▲" (C9) or DOWN button "▼" (C4). In every hold-
ing second, LCD clock display changes setting by 1 minute
interval. Press UP button "▲" (C9) or DOWN button "▼" (C4)
and holding more than 1
second, the LCD clock dis-
play changes setting by 30
minutes interval.
When complete setting,
press CLOCK button (C6)
again to confirm the set-
ting. LCD CLOCK display
stops flashing.
3. TEMPERATURE DISPLAY
By pressing C/F toggle button (C8), the display will toggle
between Celsius and Fahrenheit.
4. SYNCHRONIZING FREQUENCY OF REMOTE CONTROL
WITH UNIT (If necessary)
CAUTION:
If the unit does not receive the signal from the remote con-
trol, synchronize the frequency of the remote control with
the unit in accordance with the following procedure.
Press and hold the emergency ON/OFF switch (A5) on the
unit. Continue to hold emergency ON/OFF switch and press
the power button (C1) on the remote control after 5 seconds
there will be a beep. You will hear another beep. Release
both the emergency ON/OFF switch and the power button.
Your remote control is now ready for use.
LCDI (Leakage Current Detection and Interruption) PLUG (B11)
TEST:
RESET
TEST
RESET: AFTER SOLVING THE PROBLEM
C5
C1
C2
C3
C4
WHEN CURRENT LEAKING OR
PRESSING TEST BUTTON, THE
UNIT WILL CUT OUT.
PLEASE PRESS RESET BUTTON.
OPERATING STEPS:
1. DIRECT OPEN AIR OUTLET GRILLE UPWARD UNTIL IT
LOCKS.
You can select the two levels, wide or narrow.
WARNING: Never use with closed air outlet grille.
2. PRESS POWER BUTTON (C1) TO "ON".
The unit starts the operation.
3. PRESS MODE BUTTON (C3).
Press the mode button (C3) to set your desired operation
mode "COOL", "DEHUMIDIFY", "FAN" or "AUTO".
COOLING Mode
During the "COOL" mode the air is cooled and hot air is exhaust-
ed to the outside air through the exhaust duct hoses. Adjust fan
speed and temperature to suit your desired comfort level.
NOTE: The exhaust duct hoses must vent outside the room
when using Cooling Mode.
DEHUMIDIFYING Mode
Air is dehumidified as it passes through the unit, without
being in full cooling mode.
The fan will operate in "Auto" mode. Fan speed is not ad-
justable in Dehumidifying mode operation.
NOTE: Remove the exhaust dust hoses when using
Dehumidifying Mode.
FAN Mode
The "FAN" mode provides only circulation of room air, so
that you cannot set the room temperature.
NOTE: The unit does not need to be vented in Fan mode.
AUTO Mode
To turn on the unit chooses "Auto" mode. The unit will
switch its operation mode and fan speed automatically
based on the environment temperature.
4. SET TEMPERATURE
Set the desired room temperature by pressing UP button
"▲" (C9) or DOWN button "▼" (C4). The setting range is
C6
from 64˚F (18˚C) to 90˚F (32˚C). The display is set tempera-
C7
ture only.
NOTE: When choosing AUTO, DEHUMIDIFY or FAN MODE,
C8
temperature setting button is invalid.
C9
5. SET FAN SPEED
Press the fan speed button (C2) to set the desired air flow rate.
Auto [
] ........... Operation at auto mode
High [
] ........... Operation at a high air flow
Med [
] ........... Operation at a medium air flow
Low [
] ........... Operation at a low air flow
6. AIR DEFLECTION (Fig. E)
The vertical louver (A4) may be set on right and left manual-
ly in desired direction.
7. STOP OPERATION
Press the Power button (C1).
TIMER OPERATION
Press the TIMER button (C7) when the unit is on, comes to OFF
Timer.
Press the TIMER button (C7) when the unit is off, comes to ON
Timer.
Set the desired time by pressing UP button "▲" (C9) or DOWN
button "▼" (C4) and press the TIMER button again. The blue
LED will light in the Emergency ON/OFF switch.
To cancel OFF Timer or ON Timer, press the Power button
(C1).
Timer setting range is 1 ~ 12 hours.
""00""= No timer setting.
EMERGENCY ON/OFF SWITCH (LED SCREEN) (A5)
This switch is used when the unit needs temporary ON/OFF.
When pressing the Emergency ON/OFF switch (A5), the unit
starts operation. The operation mode and the fan speed mode
are set at Auto.
Press the Emergency ON/OFF switch (A5) again, the unit stops
operation.
2
ENGLISH

Hide quick links:

Advertisement

Table of Contents
loading