Hydraulic Pump

Fluid Change

This transaxle is designed with an external filter for
ease of maintenance. To ensure constant fluid quality
levels and longer life an oil filter change interval of
every 200 hours is recommended.
The following procedure can be performed with the
pump installed in the vehicle, and the vehicle on level
ground. Apply the bypass valve and lock the vehicle
parking brake.
1.
Place an oil drain pan with a two gallon capacity
beneath the oil filter. Remove the oil filter from the
pump.
2.
After the oil has drained, wipe the filter base
surface off and apply a film of new oil to the gasket
of the new replacement filter.
3.
Install the new filter by hand, turn ¾ to one full
turn after the filter gasket contacts the filter base
surface.
4.
Drain old oil filters of all free-flowing oil prior to
disposal. Place used oil in appropriate containers
and dispose of it in accordance with laws in your
area.
5.
Remove the cap from the pump's expansion tank
located on the vehicle frame.
6.
Fill reservoir with SAE 10W30 oil to just above
the MIN-ADD line on the reservoir. After purging,
check levels and add oil if necessary.
7.
Reinstall the tank cap by hand. Do not overtighten.
8.
Proceed to the purge procedure.

Purging

Due to the effects air has on efficiency in hydrostatic
drive applications, it is critical that it is purged from the
system.
These purge procedures should be implemented
any time a hydrostatic system has been opened to
facilitate maintenance or any additional oil has been
added to the system.
The resulting symptoms in hydrostatic systems may
be:
Noisy operation.
lack of power or drive after short term operation.
High operation temperature and excessive
expansion of oil.
Before starting, make sure the pump is at the proper
oil level. If it is not, fill to the specifications outlined
earlier.
The following procedures are best performed with the
vehicle drive wheels off the ground, then repeated
under normal operating conditions.
52
-Dixon
lUBRICATION
3
1. Pump filter
2. Pump reservoir
3. Fluid fill lines
Changing the hydraulic pump oil filter
1.
Disengage the brake if activated.
2.
With the bypass valve open and the engine
running at fast idle, slowly move the directional
control in both forward and reverse directions (5 or
6 times). As air is purged from the unit, the oil level
will drop.
3.
With the bypass valve closed and the engine
running, slowly move the directional control in
both forward and reverse directions (5 to 6 times).
Check the oil level, and add oil as required after
stopping the engine.
4.
It may be necessary to repeat Steps 2 and 3 until
all the air is completely purged from the system.
When the transaxle operates at normal noise
levels and moves smoothly forward and reverse at
normal speeds, then the transaxle is considered
purged.
5.
After the vehicle has been used two times, the oil
level should be checked while the oil is cold and
adjusted accordingly.