HP ProLiant BL280c G6 User Manual page 38

Server blade
Hide thumbs Also See for ProLiant BL280c G6:
Table of Contents

Advertisement

The HP Smart Array P712m Controller option does not support hard drive activity LEDs when installed in the
HP ProLiant BL280c G6 Server Blade.
Item
Description
HP Smart Array P712m Controller
1
SAS connector 2
2
SAS connector 1
3
Hard drive 2
4
Hard drive connector 2
5
Hard drive connector 1
6
Hard drive 1
7
Hard drive power connectors (2)
8
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
To install the component:
Power down the server blade (on page 11).
1.
Remove the server blade (on page 12).
2.
Remove the access panel (on page 13).
3.
If installed, disconnect the hard drive power and data cables from the system board
4.
connector
identification" on page 9).
Remove the air baffle.
5.
Do one of the following:
6.
Remove the hard drive spacer from each hard drive bay.
o
Remove all SATA hard drives and hard drive spacers from each hard drive bay.
o
CAUTION:
When installing SAS hard drives in the server blade, always install the standard hard
drive screws provided with the server blade. Installing the long hard drive screws, located on the
hard drive spacer, can damage the hard drive.
("Hard drive
Hardware options installation 38