Tank Assembly; Pl750/2S Placement And Installation; Installation Of Tank Feet; Installation Of Tank Temperature Sensor At Mb2 Measuring Point - Buderus Logalux PL750 Installation And Maintenance Instruction

Solar combi-tank for dhw and space heating
Table of Contents

Advertisement

4

Tank Assembly

4.1
PL750/2S Placement and
Installation
For easier installation of the solar tempera-
ture sensor, install the sensor before you
bring the solar combi-tank up-right
(Æ Section 4.1.2).
4.1.1

Installation of tank feet

V Carefully lay the tank on its side and remove the feet
screws [1] from the pallet. Discard the pallet.
V Screw the feet screws [1] back into the tank feet
approx. ¾ in (20 mm)
V Check to make sure the drain valve [2] is closed and
the bolts for the hand cover are appropriately fastened.
V Put solar tank straight-up and level by adjusting the
tank bolts.
4.1.2
Installation of tank temperature sensor at
MB
Measuring Point
2
Install the temperature sensor before you in-
stall the insulation jacket.
In order to insure the proper function of the
solar control system, install the temperature
sensor in the MB
2
V Insert the solar temperature sensor [2] into the dry well
at the bottom of the tank at location MB
clean-out cover [4]. Push the sensor wire [1] the entire
length of the well until it meets resistance.
Logalux PL750/2 S - Changes may be made following technical improvements!
measuring point.
[3] next to the
2
Fig. 7
Installation of tank bolts
1
Tank feet screws
2
Drain valve
3
2
4
1
Fig. 8
Measuring point MB
1
Sensor Wire
2
Solar temperature sensor
3
Measuring point MB
2
4
Lower clean-out cover
4
Tank Assembly
6 720 615 217-13.1RS
(solar sensor dry well)
2
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Logalux pl750 2 s

Table of Contents