HOSHIZAKI provides this manual primarily to assist qualified service technicians in the installation, maintenance and service of the icemaker. Should the reader have any questions or concerns which have not been satisfactorily addressed, please call or write to the HOSHIZAKI Technical Support Department for assistance.
• Please review this manual. It should be read carefully before the icemaker is installed and operated. Only qualified service technicians should install, service and maintain the icemaker. This manual should be made available to the technician prior to installation, maintenance or service. •...
[a] KM-2000SWH3 [a] KM-2000SWH3 [a] KM-2000SWH3 [a] KM-2000SWH3 [a] KM-2000SWH3 Note: When used with a storage bin not recommended by Hoshizaki, the icemaker needs the space at the bottom opening as in the illustration.
[b] KM-2000SRH3 [b] KM-2000SRH3 [b] KM-2000SRH3 [b] KM-2000SRH3 [b] KM-2000SRH3 Note: When used with a storage bin not recommended by Hoshizaki, the icemaker needs the space at the bottom opening as in the illustration.
6) See the Nameplate on the Rear Panel, and check that your voltage supplied corresponds with the voltage specified on the Nameplate. 7) This icemaker needs a storage bin. The recommended storage bin is HOSHIZAKI ICE STORAGE BIN, Model B-800 series.
3. LOCATION 3. LOCATION 3. LOCATION 3. LOCATION 3. LOCATION This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within +45°F to +100°F; Normal operating water temperature should be within +45°F to +90°F. Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect production capacity.
Page 10
Before operating the icemaker, the Bin Control Thermostat must be installed correctly. 5) Install the Bin Control Thermostat as follows. See Figures 3a, b and c. (a) Remove the Tie securing the Bulb Holder. Remove the Thermostat Bracket (F) from the Shipping Hook by lifting up the Bracket (F) and shifting it to the right.
Page 11
(h) Remove the Baffle from the Bin. (i) Remove the two screws holding the Bulb Holder (C) to the Thermostat Bracket (E). If a Hoshizaki Bin is being used: If a Hoshizaki Bin is being used: If a Hoshizaki Bin is being used:...
6) Level the icemaker/Storage Bin in both the left-to-right and front-to-rear directions. Adjust the Ice Bin Legs to make the icemaker level. 7) Place the panels in position. 5. INSTALLATION OF THE SECOND UNIT - See Figures 4 and 5 5.
Page 13
9) Insert the plug of the upper unit into the receptacle of the upper unit on the Bracket until it locks in place. 10) Place the panels in position. Fig. 5b (with Non-Hoshizaki Bin) Fig. 5b (with Non-Hoshizaki Bin) Fig. 5b (with Non-Hoshizaki Bin) Fig.
6. ELECTRICAL CONNECTION 6. ELECTRICAL CONNECTION 6. ELECTRICAL CONNECTION 6. ELECTRICAL CONNECTION 6. ELECTRICAL CONNECTION 1. Electrical connection must be made in accordance with the instructions on a “WARNING” tag, provided with the pig tail leads in the Junction Box. 2.
7. INSTALLATION OF REMOTE CONDENSER UNIT 7. INSTALLATION OF REMOTE CONDENSER UNIT 7. INSTALLATION OF REMOTE CONDENSER UNIT 7. INSTALLATION OF REMOTE CONDENSER UNIT 7. INSTALLATION OF REMOTE CONDENSER UNIT [a] CHECKS BEFORE INSTALLATION [a] CHECKS BEFORE INSTALLATION [a] CHECKS BEFORE INSTALLATION [a] CHECKS BEFORE INSTALLATION [a] CHECKS BEFORE INSTALLATION 1) Unpack and remove shipping carton, tape(s) and packing.
The two copper tubings should be insulated separately. See Fig. 9. • A connector kit “OS-QUICK” is available for field-fabricated lines from HOSHIZAKI AMERICA . • R-404A precharged tubing kits, available as optional equipment, are recommended.
3) Connect the Fan Motor leads in the Junction Box of the remote condenser unit to the Fan Motor leads in the Junction Box of the HOSHIZAKI remote air-cooled icemaker. 4) Install a ground wire from the icemaker to the remote condenser unit.
[e] STACKING CONDENSER UNIT [e] STACKING CONDENSER UNIT [e] STACKING CONDENSER UNIT [e] STACKING CONDENSER UNIT [e] STACKING CONDENSER UNIT 1) Secure the lower condenser unit to the Legs with eight bolts (not included). 2) Attach the upper condenser unit on the top of the lower. 3) Secure the upper condenser unit with the four screws provided.
8. WATER SUPPLY AND DRAIN CONNECTIONS - See Fig. 12 8. WATER SUPPLY AND DRAIN CONNECTIONS - See Fig. 12 8. WATER SUPPLY AND DRAIN CONNECTIONS - See Fig. 12 8. WATER SUPPLY AND DRAIN CONNECTIONS - See Fig. 12 8.
9. FINAL CHECK LIST 9. FINAL CHECK LIST 9. FINAL CHECK LIST 9. FINAL CHECK LIST 9. FINAL CHECK LIST 1) Is the icemaker level? 2) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F all year around? 3) Is there at least a 6"...
10. START UP 10. START UP 10. START UP 10. START UP 10. START UP 1. All parts are factory-adjusted. Improper adjustments may result in failure. 2. If the unit is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the Compressor.
11. PREPARING THE ICEMAKER FOR LONG STORAGE 11. PREPARING THE ICEMAKER FOR LONG STORAGE 11. PREPARING THE ICEMAKER FOR LONG STORAGE 11. PREPARING THE ICEMAKER FOR LONG STORAGE 11. PREPARING THE ICEMAKER FOR LONG STORAGE When shutting off the icemaker for an extended time, drain out all water from the water tank and remove the ice from the Storage Bin.
Page 24
4) Close the Potable Water Supply Line Shut-off Valve and open the Potable Water Supply Line Drain Valve. See Fig. 12. 5) Allow the line to drain by gravity. 6) Attach compressed air or carbon dioxide supply to the Potable Water Line Drain Valve. 7) Move the Control Switch to the “ICE”...
1. CLEANING INSTRUCTIONS 1. CLEANING INSTRUCTIONS 1. CLEANING INSTRUCTIONS 1. HOSHIZAKI recommends cleaning this unit at least once a year. More frequent cleaning, however, may be required in some existing water conditions. 2. To prevent injury to individuals and damage to the icemaker, do not use ammonia type cleaners.
1) Dilute approximately 38 fl. oz. of recommended cleaner Hoshizaki “Scale Away” or “LIME-A-WAY,” (Economics Laboratory, Inc.) with 7 gal. of water. 2) Remove all ice from the Evaporator and the Storage Bin. Note: To remove cubes on the Evaporator, turn off the power supply and turn it on after 3 minutes.
21) Move the Control Switch to the “WASH” position. 22) Replace the Front Panel in its correct position. 23) Turn on the power supply to rinse off the cleaning solution. 24) Turn off the power supply after 5 minutes. 25) Remove the Front Panel and the Insulation Panel. 26) Remove the Cap located on the front bottom part of the Ice Dropping Hole.
9) Close the Cleaning Valve. 10) Move the Control Switch to the “ICE” position. 11) Replace the Front Panel in its correct position. 12) Clean the Storage Bin with water. 13) Turn on the power supply, and start the automatic icemaking process. 2.
Page 29
HOSHIZAKI HOSHIZAKI AMERICA, INC. HOSHIZAKI AMERICA, INC. HOSHIZAKI AMERICA, INC. HOSHIZAKI AMERICA, INC. HOSHIZAKI AMERICA, INC. 618 HIGHWAY 74 SOUTH 618 HIGHWAY 74 SOUTH 618 HIGHWAY 74 SOUTH 618 HIGHWAY 74 SOUTH 618 HIGHWAY 74 SOUTH PEACHTREE CITY, GA 30269...