Km-1301Swh-E (Water-Cooled) - Hoshizaki STACKABLE CRESCENT CUBER KM-1301SAH-E Service Manual

Stackable crescent cuber
Hide thumbs Also See for STACKABLE CRESCENT CUBER KM-1301SAH-E:
Table of Contents

Advertisement

2. KM-1301SWH-E (water-cooled)

APPROXIMATE ICE
PRODUCTION PER 24 HR.
lbs./day kg./day
APPROXIMATE ELECTRIC
CONSUMPTION
watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
3
gal./day
m
/day
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
2
PSIG
kg/cm
G
SUCTION PRESSURE
2
PSIG
kg/cm
G
TOTAL HEAT OF REJECTION FROM CONDENSER
TOTAL HEAT OF REJECTION FROM COMPRESSOR
WATER FLOW FOR CONDENSER
PRESSURE DROP OF COOLING WATER LINE
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
AMBIENT TEMP.
(ºF/ºC)
70/21
1330
80/27
1310
90/32
1304
100/38
1281
70/21
80/27
90/32
100/38
70/21
1335
80/27
1404
90/32
1425
100/38
1741
70/21
80/27
90/32
100/38
70/21
80/27
90/32
100/38
70/21
238
80/27
239
90/32
239
100/38
244
70/21
50
80/27
50
90/32
51
100/38
51
33
WATER TEMP. (ºF/ºC)
50/10
70/21
603
1304
594
1269
591
1240
581
1222
1780
1780
1780
1780
1780
1780
1790
1786
5.05
1425
5.31
1544
5.40
1643
6.59
1805
31
32
32
33
32
34
33
34
4.2
3.7
3.8
3.0
3.7
2.4
3.1
2.4
16.7
239
16.8
240
16.8
241
17.2
244
3.5
51
3.5
51
3.6
52
3.6
52
19,382 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
2,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
117 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
less than 10 PSIG
90/32
591
1239
562
576
1189
539
562
1165
528
554
1096
497
1799
1810
1806
1830
5.40
1971
7.46
5.85
2324
8.80
6.22
2335
8.84
6.83
2971
11.25
34
35
36
38
3.4
2.9
2.2
2.1
16.8
249
17.5
16.9
256
18.0
16.9
255
17.9
17.2
267
18.8
3.6
52
3.6
3.6
52
3.7
3.7
53
3.7
3.7
54
3.8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-1301srh-eKm-1301swh-e

Table of Contents