4. 12 Hour Drain Cycle / Drain Switch

1 hour timer initiates cycle or the control switch is moved to the "DRAIN" position.
90 seconds after initiation, the compressor and condenser fan motor stop, 60 seconds
later the gear motor stops. Once the gear motor protect relay de-energizes, the drain
water valve opens. In the 1 hour drain cycle, the drain water valve remains open for
0 minutes. When the drain cycle is initiated manually using the control switch, the drain
valve remains open until the control switch is moved to the "ICE" position.
1 Hour Drain Cycle