C. Sequence of Electrical Circuit – Ice Making
1. Fill Cycle
With the power switch in the "ON" position and the control switch in the "ICE" position,
the inlet water valve energizes and the reservoir fills with water until the upper float
switch closes.
DCM-500BAH
DCM-500BWH
(Control Board)
WIRE COLOR CODE
BK
BLACK
O
ORANGE
W/BK WHITE/BLACK
BR
BROWN
P
PINK
W/BR WHITE/BROWN
BU
BLUE
R
RED
W/BU WHITE/BLUE
DBU
DARK BLUE
V
VIOLET
W/O
GY
GRAY
W
WHITE
W/R
LBU
LIGHT BLUE
Y
YELLOW
5
DCM-500BAH-OS
DCM-500BWH-OS
(Control Board)
WHITE/ORANGE
WHITE/RED