Dcm-500Bah-Os - Hoshizaki DCM-500BAH Service Manual

Cubelet icemaker / dispenser
Hide thumbs Also See for DCM-500BAH:
Table of Contents

Advertisement

2. DCM-500BAH-OS

AC SUPPLY VOLTAGE
COMPRESSOR
GEAR MOTOR
FAN MOTOR
AGITATING MOTOR
DISPENSING MOTOR
OTHERS
MAXIMUM FUSE SIZE
MAX. HACR BREAKER (USA ONLY)
MAX. CIRC. BREAKER (CANADA ONLY)
MINIMUM CIRCUIT AMPACITY
APPROXIMATE ICE PRODUCTION
PER 24 HR.
lbs./day ( kg/day )
Reference without * marks
SHAPE OF ICE
ICE QUALITY
APPROXIMATE STORAGE CAPACITY
ELECTRIC & WATER CONSUMPTION
ELECTRIC
W (kWH/100 lbs.)
POTABLE WATER
gal./24HR
(gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
EXTERIOR FINISH
WEIGHT
CONNECTIONS - ELECTRIC
- WATER SUPPLY
- DRAIN
ICE MAKING SYSTEM
HARVESTING SYSTEM
ICE MAKING WATER CONTROL
COOLING WATER CONTROL
DISPENSER CONTROL SYSTEM
BIN CONTROL SYSTEM
COMPRESSOR
CONDENSER
EVAPORATOR
REFRIGERANT CONTROL
REFRIGERANT CHARGE
DESIGN PRESSURE
P.C. BOARD CIRCUIT PROTECTION
COMPRESSOR PROTECTION
GEAR MOTOR PROTECTION
REFRIGERANT CIRCUIT PROTECTION
LOW WATER PROTECTION
ACCESSORIES - SUPPLIED
- REQUIRED
OPERATING CONDITIONS
Note: We reserve the right to make changes in specifications and design without prior
notice.
115/60/1
120 V
7.9 RLA
120 V
1.6 FLA
120 V
0.6 FLA
120 V
0.9 FLA
120 V
0.9 FLA
120 V
0.2 A
20 A
20 A
20 A
20 A
Ambient
WATER TEMP. (°F)
Temp. (°F)
50
70
*525 (238)
80
461 (209)
90
396 (179)
100
340 (154)
Cubelet (Compressed Flake Ice)
Apprx. 90% Ice (90/70° F, CONDUCTIVITY 200 µs/cm)
40 lbs.
90/70°F
70/50°F
1055 (6.6)
985 (4.4)
46 (11.9)
64 (11.9)
26" x 22-1/2" x 40" ( 661 x 571 x 1016 mm)
Stainless Steel, Galvanized Steel (Rear)
NET 251 lbs. (114 kg), Shipping 276 lbs. (125 kg)
Permanent Connection
Inlet
1/2" FPT
Outlet
3/4" FPT x2
Auger type
Direct Driven Auger ( 1/6 HP Gear Motor )
Float Switch
N/A
Photoelectric Sensor (Infrared)
Mechanical Bin Control ( Proximity Sw. )
Hermetic, Model RS43C2E-CAA-219
Air-cooled, Fin and tube type
Copper Tube on Cylinder
Thermostatic Expansion Valve
R404A
1 lb 4.1 oz. (570g)
High 460 PSIG
High Voltage Cut-out Relay
Auto-reset Overload Protector
Auto-reset Thermal Protector
Fuse
Auto-reset High Pressure Control Switch
Float Switch and Timer
Spare Fuse
Legs
VOLTAGE RANGE
AMBIENT TEMP.
WATER SUPPLY TEMP.
WATER SUPPLY PRESSURE
6
51 LRA
1/6 HP
30 W
55 W
55 W
70
90
510 (231)
485 (220)
438 (199)
416 (189)
*385 (175)
358 (162)
323 (147)
*304 (138)
Low 290 PSIG
104-127 V
45-100 F
45-90 F
10-113 PSIG