Hour Drain Cycle / Drain Switch - Hoshizaki CUBELET ICEMAKER/DISPENSER DCM-750BAH Service Manual

Cubelet icemaker / dispenser
Hide thumbs Also See for CUBELET ICEMAKER/DISPENSER DCM-750BAH:
Table of Contents

Advertisement

4. 12 Hour Drain Cycle / Drain Switch

 hour timer initiates cycle or the control switch is moved to the "DRAIN" position.
90 seconds after initiation, the compressor and condenser fan motor stop, 60 seconds
later the gear motor stops. Once the gear motor protect relay de-energizes, the drain
water valve opens. In the  hour drain cycle, the drain water valve remains open for
0 minutes. When the drain cycle is initiated manually using the control switch, the drain
valve remains open until the control switch is moved to the "ICE" position.
DCM-750BAH,
DCM-750BWH
 Hour Drain Cycle
Manual Drain Cycle
WIRE COLOR CODE
BK
BLACK
BR
BROWN
BU
BLUE
DBU
DARK BLUE
GY
GRAY
LBU
LIGHT BLUE
O
ORANGE
W/BK WHITE/BLACK
P
PINK
W/BR WHITE/BROWN
R
RED
W/BU WHITE/BLUE
V
VIOLET
W/O
WHITE/ORANGE
W
WHITE
W/R
WHITE/RED
Y
YELLOW
8
DCM-750BAH-OS,
DCM-750BWH-OS
 Hour Drain Cycle
Manual Drain Cycle

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcm-750bah-osDcm-750bwhDcm-750bwh-os

Table of Contents